C H A P T E R 2 Installing the 7110/7115 Free-Standing or in a Rack
2-3
3. Position the 7110/7115 in the desired space of your 19” rack and
attach the front flange of each mounting bracket to the rack with
two screws each. (Rack-mounting screws are not provided.)
Free-Standing Installation
1. Attach the provided self-adhesive rubber feet to the 7110/7115’s
bottom.
2. Place the 7110/7115 on a flat surface and make sure that there is
adequate airflow surrounding the unit (allow at least one inch of
air space on all sides).
Network Connections
1. Use the “Network Cable Requirements” table near the beginning
of this guide to select and install the the appropriate cables.
NOTE: Never connect
both ports to the same
network segment (e.g., to
the same hub or switch).
Doing so creates a
feedback loop that
adversely effects network
bandwidth.
2. Connect the provided power cable to the back of the unit. (There
is no power switch.) Under normal circumstances, the 7110/7115
requires approximately 30 seconds to boot. When the boot is
complete, the unit’s Power LED is steadily illuminated. (If the
Power LED is not steadily illuminated, see Chapter 9,
“Troubleshooting.)
3. If the Inline LED is neither steadily illuminated or blinking, press
the Bypass switch.
4. At this point both the Network and Server LEDs should be
steadily illuminated. If not, please see Chapter 9,
“Troubleshooting.
Figure 2-2: Wiring Connections
Intel® NetStructure™ 7110/7115 e-Commerce Accelerators
Hub/Router/Switch
Server