C H A P T E R 4 Scenario 3—Multiple 7110/7115s, Cascaded
4-9
9. Specify a filename for the received file and click OK. The
operation concludes and the normal prompt reappears.
Use Ctrl-X to kill transmission
Export successful!
Intel 7115>
10.Connect to the second 7110/7115, either through the console
connection or another window (if both are connected to the same
PC).
11. Import the configuration. Use the import config command to
begin the process. Select xmodem (x) and press Enter to begin
the import process.
Intel 7115> import config
Import protocol: (paste, xmodem, uudecode)
[paste]: x <Enter>
Use Ctl-X to cancel upload
12.Select Send from the HyperTerminal§ Transfer menu.
13.Type or use the Browse button to specify the file to send.
14.Select xmodem as the sending protocol.
15.Click the Send button. The transfer completes and then you are
prompted to verify that you wish to install this configuration.
Do you want to install this config ? [y]: y
16.After verification (y) or refusal (n), the prompt reappears.
Intel 7115>
17.Save the configuration.
Intel 7115>config save
Saving configuration to flash...
Configuration saved to flash
Intel 7115>
18.Repeat steps 11-17 for any additional 7110/7115s. On the last
7110/7115 in the chain, disable spilling with the set spill disable
command.