Intel A31032-001 TV Mount User Manual


 
C H A P T E R 2 Intel® NetStructure™ 7110/7115 e-Commerce Accelerator User Guide
2-6
Troubleshooting
Server and Network LEDs
If either the Network or Server LED fails to illuminate using either
straight-through or crossover network cables, the problem may be
elsewhere in the network. Verify by wiring around the 7110/7115.
Inline LED
The Fail-through switch allows you to control what happens in the
event of a failure. It is located in a recess between the Network and
Server connectors. Use a small screwdriver or paper clip to
manipulate the switch. The two options are:
Allow traffic to flow through the 7110/7115 unprocessed. (Fail-
through mode, indicated by a steadily illuminated Inline LED.)
Block traffic flow through the 7110/7115 entirely. (Fail-safe
mode, indicated by a blinking Inline LED.)
Please see Appendix B for a table describing all permutations of LED
operation.
Continuing Configuration
This concludes basic configuration of the 7110/7115. To configure
the unit for production please continue with Chapter 3, Theory of
Operations, or Chapter 4, Scenarios.