Sharp SF-1020 DVD Player User Manual


 
NO
YES
NO
YES
NO
YES
NO
YES
NO
YES
1
Is the toner
density reference value
recorded?
Use Sim 43-01 to set the
fusing temperature
Use Sim 22-07 to set the
developer replacement cycle
counter to the specified value
Use Sim 22-06 to set the
developer counter
Use Sim 21-01 to set the
maintenance cycle to the
specified value
Use Sim 26-06 to set the
desitination specifications
Use Sim 26-13 to set the
operation mode in warm-up
Is the copy
density adjustment
value recorded?
Use Sim 46-01 to set the copy
density adjustment value
Is the vertical
copy magnification
ratio adjustment value
recorded?
Use Sim 48-01 to the
vertical copy magnification
ratio adjustment value
Is the
horizontal copy magnification
ratio adjustment value
recorded?
Use Sim 48-02 to set the
horizontal copy magnification
ratio adjustment value
Is the adjustment
value of contact pressur
between the main body resist
roller and the copy paper
recorded?
Use Sim 51-02 to set the adjustment
value of contact pressure between
the main body resist roller and the
copy paper
Make a copy and
adjust the copy
density
Make a copy and
adjust the vertical
magnification ratio
Make a copy and
adjust the horizontal
copy magnification ratio
Make a copy and adjust the
contact pressure between
the main body resist roller
and the copy paper
*1) For setting, refer to the service
memory data recoding sheet
Use Sim 25-2 to set the
toner density reference value
NO
YES
NO
YES
Are the image
lead edge position
adjustment value and
the resist roller ON
timing adjustment value
recorded?
Use Sim 50-01,50-02 to set the image
lead edge position adjustment value and
the resist roller ON timing adjustment
value
Make a copy and adjust the
image lead efge position and the
resist roller ON timing
Is the void
amount adjustmant
value recorded?
Use Sim 50-02 to set the void amount
adjustment value
End
Make a copy and adjust the
void amount
Use Sim 47 to set the AE
sensor gain is auto-matically
adj
10 – 2