Teledyne T703U VCR User Manual


 
Table of Contents Teledyne API T703/T703U Calibrator Operation Manual
x
4.5.1.3. Setting the Repeat Count for a Sequence .....................................................................................55
4.5.1.4. Using the Internal Clock to Trigger Sequences.............................................................................56
4.5.1.5. Setting Up Control Inputs for a Sequence......................................................................................59
4.5.1.6. Setting Up Control Outputs for a Sequence...................................................................................60
4.5.1.7. Setting the Progress Reporting Mode for the Sequences..............................................................61
4.5.2. Adding Sequence Steps ........................................................................................................................62
4.5.2.1. The GENERATE Step ....................................................................................................................63
4.5.2.2. The STANDBY Step.......................................................................................................................64
4.5.2.3. The DURATION Step .....................................................................................................................64
4.5.2.4. The EXECSEQ Step.......................................................................................................................65
4.5.2.5. The CC OUTPUT Step...................................................................................................................66
4.5.2.6. Deleting or Editing an Individual Step in a Sequence ....................................................................67
4.5.3. Deleting a Sequence .............................................................................................................................68
4.6. SETUP CFG ............................................................................................................................................69
4.7. SETUP CLK.............................................................................................................................................70
4.7.1. Setting the Internal Clock’s Time and Day ............................................................................................70
4.7.2. Adjusting the Internal Clock’s speed......................................................................................................71
4.8. SETUP PASS..........................................................................................................................................72
4.9. SETUP DIAG TEST CHAN OUTPUT: Using the TEST Channel Analog Output...............................74
4.9.1. Configuring the TEST Channel Analog Output......................................................................................74
4.9.1.1. The Analog I/O Configuration Submenu ........................................................................................74
4.9.1.2. Selecting a TEST Channel Function to Output ..............................................................................76
4.9.1.3. TEST Channel Voltage Range Configuration ................................................................................78
4.9.1.4. Turning the TEST Channel Over-Range Feature ON/OFF............................................................79
4.9.1.5. Adding a Recorder Offset to the TEST Channel ............................................................................80
4.9.2. TEST Channel Calibration .....................................................................................................................81
4.9.2.1. Enabling or Disabling the TEST CHANNEL Auto-Cal Feature ......................................................82
4.9.2.2. Automatic TEST Channel Calibration.............................................................................................83
4.9.2.3. Manual Calibration of the TEST Channel Configured for Voltage Ranges....................................85
4.9.3. AIN Calibration.......................................................................................................................................87
4.10. SETUP MORE VARS: Internal Variables (VARS)............................................................................88
4.11. Operating the Calibrator as an O
3
Photometer..........................................................................................90
4.11.1. Set up for Operation as an O
3
Photometer..........................................................................................90
4.12. SETUP LVL: Setting up and using LEADS (Dasibi) Operating Levels .................................................92
4.12.1. General Information about LEADS LEVELS .......................................................................................92
4.12.2. Dot commands.....................................................................................................................................92
4.12.3. Levels...................................................................................................................................................93
4.12.4. Activating an existing LEVEL...............................................................................................................93
4.12.5. Programming New LEVELS ................................................................................................................94
4.12.5.1. Creating a Generate LEVEL.........................................................................................................95
4.12.5.2. Editing or Deleting a LEVEL.........................................................................................................96
4.12.6. Configuring LEVEL Status Blocks .......................................................................................................97
5. COMMUNICATIONS .......................................................................................................... 99
5.1. Using the Analyser’s Communication Ports.................................................................................................99
5.1.1. RS-232 DTE and DCE Communication.................................................................................................99
5.1.2. Serial COM Port Default Settings and Connector Pin Assignments .................................................. 100
5.1.3. COM Port Baud Rate.......................................................................................................................... 102
5.1.4. COM Port Communication Modes...................................................................................................... 103
5.1.5. COM Port Testing ............................................................................................................................... 105
5.1.6. Machine ID.......................................................................................................................................... 106
5.1.7. Terminal Operating Modes ................................................................................................................. 107
5.1.7.1. Help Commands in Terminal Mode............................................................................................. 107
5.1.7.2. Command Syntax........................................................................................................................ 108
5.1.7.3. Data Types .................................................................................................................................. 108
5.1.7.4. Status Reporting.......................................................................................................................... 109
5.1.7.5. General Message Format............................................................................................................ 109
5.1.7.6. COM Port Password Security...................................................................................................... 110
5.2. Remote Access by Modem....................................................................................................................... 111
07223C DCN6572