A&D PD4000243 Universal Remote User Manual


 
Page 100 AD-4402
9.4.
9.4.9.4.
9.4. Initializing Parameters
Initializing ParametersInitializing Parameters
Initializing Parameters
The function initializes the parameters stored in the indicator.
The parameters are stored in the flash memory and backup RAM.
Caution
There are the kinds of reset function that must re-calibrate the indicator
Note the parameters where is stored in.
Kinds of intialization mode
Kinds of intialization Description
Initializing RAM
The backup RAM is reset. Zero point of gross display, tare
value zeroes.
Initializing material code or
recipe code
Material code and recipe code is reset.
Initializing function list It is reset parameters of function list in the flash memory.
Initializing caribration data
It is reset parameters of calibration data in the flash
memory. If this function is used, calibrate the indicator.
Initializing all parameters It resets all parameters.
The location of the parameters and objects of intialization mode
Material
code
Recipe
code
Zero
Tare
Material code
Accumulation data
Recipe code
Accumulation data
Function list
Calibration data
Backup RAM o o o o o o
Location
Flash memory o o o o
Initializing RAM o o
Initializing material code or
recipe code
o o o o
Initializing function list o
Initializing caribration data o
Intialization mode
Initializing all parameters o o o o o o o o