A&D PD4000243 Universal Remote User Manual


 
AD-4402 Page 37
7.2.1.
7.2.1.7.2.1.
7.2.1. Selection of Batch Weighing
Selection of Batch WeighingSelection of Batch Weighing
Selection of Batch Weighing
Selection of Normal Batching or Loss-in-weight
The mode can be selected at Loss-in weight at the Function list.
([Function] - [Function setting] - [Sequence] - [Basic] - [Current weighing])
[5q f- 3] [0] Normal batch weighing
[5q f- 3] [1] Loss-in weight
[5q f- 3] [2] External selection (Normal batch weighing or Loss-in weight)
External Selection (Normal batch weighing or Loss-in weight)
Normal batch weighing and Loss-in weight can be selected by a signal of the input
terminal that is set to [9] of External switch control.
(The menu [Function] - [Function setting] - [Control I/O Function] - [Input] )
Example of use: The material of 100 kg is supplied to the hopper in first step. It is
subdivided into material of 10kg.
Advise
If the mode is switched concerning a specified material only, set the hopper no. in the
material code, short the hopper no. output line and the supply/discharge switch input
line. Set the delay timer [5q f-32] to "above 0.1sec.".