7.3.2.
7.3.2.7.3.2.
7.3.2. L
LL
Loss-in
oss-inoss-in
oss-in W
W W
Weight of Sequential
eight of Sequentialeight of Sequential
eight of Sequential Mode
Mode Mode
Mode
Loss-in weight weighs the material discharged form the hopper.
The control gates (valves) can be used. (The full flow, medium flow and dribble flow)
Concerning Parameters of the Function
Selecting normal batching of sequential weighing.
[5q f- 1] [1] Sequential weighing
[Function] - [Function setting] - [Sequence] - [Basic] - [Weighing mode]
[5q f- 3] [0] Normal batch weighing
[Function] - [Function setting] - [Sequence] - [Basic] - [Loss-in weight]
Making zero display automatically when starting the sequence.
[5q f-11]
[Function] - [Function setting] - [Sequence] - [Control] - [Batch start settings]
Switching normal batching and loss-in weight from the I/O interface.
[5q f- 3] [2] External exchange
Set an input terminal to switch the mode at the I/O interface. Material
can be supplied to the hopper with three gates (valves).
[Function] - [Function setting] - [Sequence] - [Basic] - [Loss-in weight]
Checking whether is there the remainder weight for one batch weighting.
[5q f-55] [1] When the remainder weight decreases under target weight + nearly
zero, the signal "nearly zero" is output.
[Function] - [Function setting] - [Sequence] - [Setpoint (Compared value)] -
[Add final value and zero band]
[5q f-56] [1] If this is set, when the hopper is filled fully, the signal "Full" is output.
[Function] - [Function setting] - [Sequence] - [Setpoint (Compared value)] -
[Add final value and full value]