A&D PD4000243 Universal Remote User Manual


 
Page 110 AD-4402
Category address
:
[Function] - [Function setting] - [General] - [Sub-display]
Category
address
symbol
Name Descriptions
Range
and
choices
Default
5ub f 1
5ub f 2
Refer to previous pages.
5ub f 3
Bar graph location
0: Hide
1: Upper side.
2: Lower side.
0 to 2 0
5ub f 4
Ratio of graph
display
1: Gross weight to capacity.
2: Net weight to final value.
0 to 2 1
5ub f 5
Activity indicator
0: Off (Not used)
1: On (Use)
0 to 1 1
Category address
:
[Function] - [Function setting] - [General] - [Others]
Category
address
symbol
Name Descriptions
Range
and
choices
Default
othf- 1
Key lock
Set the action of each key.
Bit 1: F1 key
Bit 2: F2 key
Bit 3: F3 key
Bit 4: F4 key
Bit 5: Code recall key
Bit 6: Code set key
Bit 7: Not defined
Bit 8: Zero key
Bit 9: Tare key
Bit 10: Net / Gross key
Bit 11: Not defined
Bit 12: Off key
0: Unlock
1: Lock
0000000
00000 to
1111111
11111
00000
00000
00