A&D PD4000243 Universal Remote User Manual


 
AD-4402 Page 129
Category
address
symbol
Name Descriptions
Range
and
choices
Default
03 f- 8
04 f- 8
Address
0: Address is not used
1 to 99: Address is used
0 to 99 0
03 f- 9
Response timer
Set the waiting timer from receiving
command to transmitting a response.
0.00 to
2.55 s
0.00 s
03 f-11
RS-422 / 485
switch
1: RS-422
2: RS-485
1 to 2 1