A&D PD4000243 Universal Remote User Manual


 
AD-4402 Page 77
8.2.4.
8.2.4.8.2.4.
8.2.4. General Data Format
General Data FormatGeneral Data Format
General Data Format
This format is used at command mode and jet stream mode.
12345678910111213141516171819202122232425262728
RGRS0099 , 1234567 , 123456789
C
R
L
F
Header
Command is replayed. The replayed command is 4 characters
Code
Material code or recipe code number. The code is 4 characters
Weighing data
Data uses BCD code, is 7 figures and is not include decimal point.
When data is negative, minus sign is appended to the head.
System Monitor
Terminator
CR or CR + LF CR: 0Dh, LF: 0Ah
Header Code Weighing data
System Monitor
Terminator
2
0
:Stable
2
1
: Zero band
2
2
: Full filling
2
3
: Full flow
1 2 8 976543
2
0
: Medium flow
2
1
:Dribble flow
2
2
:Over
2
3
: Acceptable
2
0
: Discharge gate
2
1
: Weighing finish
2
2
: Recipe finish
2
3
: Discharge finish
2
0
: Under
2
1
: Internal reservation
2
2
: Internal reservation
2
3
:Mixture
2
0
: Mixture finish
2
1
: Nozzle down
2
2
:Online
2
3
: During weighing sequence
2
0
: Internal reservation
2
1
: Weighing error
2
2
:Alarm 1
2
3
:Alarm 2
2
0
: Zero error
2
1
: Out of range
2
2
: Buzzer
2
3
:During tare
2
0
: Center of zero
2
1
: Gross display
2
2
: net display
2
3
: During hold
Internal reservation
Example: 2
3
2
2
2
1
2
0
1
0
1
0 = Ah
A
SCII code = 3Ah.
Upper 4 bits are 3h always.