A&D PD4000243 Universal Remote User Manual


 
Page 128 AD-4402
Category address
:
[Function] - [Function setting] - [Option] - [slot
n
] - [OP-03] or
[Function] - [Function setting] - [Option] - [slot
n
] - [OP-04]
OP-03: Option RS-422 / 485 Serial Interface
OP-04: Option RS-232C Serial Interface
slot
n : slot number
Category
address
symbol
Name Descriptions
Range
and
choices
Default
03 f- 1
04 f- 1
Output data
When jet stream mode of Coumnication
mode [r5 f- 2] is used, the 1, 2, 3 can
select. And if freeze mode is used in jet
stream mode, output is stoped.
1: Weighing value
2: Gross value
2: Net value
4: Tare value
5: Gross value/ Net value/ Tare value
6: Weighing value with material code
7: Gross value with material code
8: Net value with material code
9: Tare value with material code
10: Gross value/ Net value/ Tare value
with material code
1 to 10 1
03 f- 2
04 f- 2
Comunication
mode
1: Stream mode
2: Auto print mode
3: Manual print mode
4: Print at total
5: Jet stream mode
6: Command mode
1 to 6 6
03 f- 3
04 f- 3
Baud rate
1: 600 bps
2: 12000 bps
3: 2400 bps
4: 4800 bps
5: 9600 bps
6: 19200 bps
7: 38400 bps (Command mode can not
select)
1 to 7 5
03 f- 4
04 f- 4
Parity check
0: Not used
1: Odd
2: Even
0 to 2 0
03 f- 5
04 f- 5
Charactor length
7: 7 bits
8: 8 bits
7, 8 8
03 f- 6
04 f- 6
Stop bits
1: 1 bit
2: 2:bits
1 to 2 1
03 f- 7
04 f- 7
Terminator
1: CR CR: 0Dh
2: CR LF LF: 0Ah
1 to 2 2