A&D PD4000243 Universal Remote User Manual


 
Page 120 AD-4402
Category address
:
[Function] - [Function setting] - [Control I/O Function] - [Input]
The list to assign the function for the input terminal of the I/O
No. Function description Read No. Function description Read
0 No function
- 26 Clear totals of active recipe
code
Edge
1 Zero Edge 27 Clear totals of all recipe code Edge
2 Zero clear Edge 28 Safety check input 1 Level
3 Tare Edge 29 Safety check input 2 Level
4 Tare clear Edge 30 Safety check input 3 Level
5 Batch start Edge 31 Safety check input 4 Level
6 Recipe start Edge 32 Safety check input 5 Level
7 Discharge start Edge 33 Safety check input 6 Level
8 Mixtire start Edge 34 Safety check input 7 Level
9
External switch control
0: Normal bach
1: Loss-in weight
Level 35 Safety check input 8 Level
10 Manual free fall compensation Edge 36 Foced batch finish Edge
11 Accumulation command Edge 37 Foced recipe finish Edge
12 Cancel the last result Edge 38 Foced discharge finish Edge
13 Emergency stop Level 39 Manual full flow Level
14
Material / Recipe code,
BCD 1
Level 40 Manual medium flow Level
15
Material / Recipe code,
BCD 2
Level 41 Mnaual dribble flow Level
16
Material / Recipe code,
BCD 4
Level 42 Manual discharge Level
17
Material / Recipe code,
BCD 8
Level 43 Manual mixture Level
18
Material / Recipe code,
BCD 10
Level 44 Error reset Edge
19
Material / Recipe code,
BCD 20
Level 45 Hold Level
20
Material / Recipe code,
BCD 40
Level 46 Key unlock Level
21
Material / Recipe code,
BCD 80
Level 47 Manual print command Edge
22 Pause
Edge 48
Code recall external switch control
OFF: key, ON: digital switch
Level
23 Restart Edge 49 Recipe interrupt Level
24
Clear totals of active material
code
Edge 50 Net / gross Edge
25 Clear totals of all material code Edge