A&D PD4000243 Universal Remote User Manual


 
AD-4402 Page 71
7.5.12.
7.5.12.7.5.12.
7.5.12. Graphic Status Indicator
Graphic Status IndicatorGraphic Status Indicator
Graphic Status Indicator
The indicator can display weighing status, result on the graphic indicator.
Concerning Parameters of the Function
Using graphic indicator
[5ubf- 5] Activity indicator
[Function] - [Function setting] - [General] - [Sub display]
7.5.13.
7.5.13.7.5.13.
7.5.13. Memory
MemoryMemory
Memory Backup
Backup Backup
Backup
The indicator has two kinds of memory.
Flash memory The memory is used to store the important data without power
supply that the count of re-writing them is few.
Life of re-writing them is approximately 100,000 times or more.
Data example: Calibration data, Function data
Backuped RAM The memory is used to store temporary data that the count of re-
writing them is many.
Life of battery is approximately 10 years at 25 , normal use
Data example: Tare value, accumulation data, re-zero data
When re-writing data, the sequence is stopped.
Material code and recipe code can store in flash memory or backup RAM.
Concerning Parameters of the Function
Selecting the memory for material code or recipe code
[0tHf-11] Save data
[Function] - [Function setting] - [General] - [Other]
Graphic indicator
Over UnderAcceptable Full flow Medium flow Dribble flow