A&D PD4000243 Universal Remote User Manual


 
Page 84 AD-4402
Terminals
When weighing display, gross display, net display and tare display [01f- 1] [1,
2, 3, 4] is used, the function of terminals are as follows:
A1 1 B1 2
Unit Unit 1 Unit 2
A2 4 B2 8
blank
00
A3 10 B3 20
kg
00
A4 40 B4 80
t
01
A5 100 B5 200
g
11
A6 400 B6 800
A7 1,000 B7 2,000
A8 4,000 B8 8,000
A9 10,000 B9 80,000
A10 40,000 B10 80,000
A11 100,000 B11 200,000
A12 400,000 B12 800,000
A13 Over B13 Positive polarity
A14 Stable B14 Net
A15 Decimal point 0.0 B15 Decimal point 0.0
A16 Decimal point 000.0 B16 Decimal point 000.0
A17 Unit 1 B17 Unit 2
A18 Strobe B18 Hold input
A19 Common ground B19 Common ground
A20 Frame ground B20 Frame ground
When accumulation weight and accumulation counts [01f- 1] [5, 6, 7, 8] is used,
the function of terminals are as follows:.
A1 1 B1 2
A2 4 B2 8
A3 10 B3 20
A4 40 B4 80
A5 100 B5 200
A6 400 B6 800
A7 1,000 B7 2,000
A8 4,000 B8 8,000
A9 10,000 B9 80,000
A10 40,000 B10 80,000
A11 100,000 B11 200,000
A12 400,000 B12 800,000
A13 1,000,000 B13 2,000,000
A14 4,000,000 B14 8,000,000
A15 10,000,000 B15 20,000,000
A16 40,000,000 B16 80,000,000
A17 Over B17 Positive polarity
A18 Strobe B18 Hold input
A19 Common ground B19 Common ground
A20 Frame ground B20 Frame ground