A&D PD4000243 Universal Remote User Manual


 
AD-4402 Page 53
7.3.9.
7.3.9.7.3.9.
7.3.9. Mixture Sequence
Mixture SequenceMixture Sequence
Mixture Sequence
The mixture sequence is used to mix or stir it. The signal is output from the I/O
terminal set to mixing. The timing of weighing finish, discharge finish and mixture
finish can be selected.
Concerning Parameters of the Function
Using the mixture sequence
[0utf-nn] [12] Mixture
nn: terminal number of I/O.
[Function] - [Function setting] - [Control I/O] - [Output]
Relay output (OP-02), parallel I/O (OP-05) can be used.
Mixing it at weighing finish
[5q f-14]
[Function] - [Function setting] - [Sequence] - [Control] - [
Batch finish
action
]
Mixing it after discharge
[5q f-15]
[Function] - [Function setting] - [Sequence] - [Control] - [
Discharge finish
action
]
Mixing it after formula
[5q f-17]
[Function] - [Function setting] - [Sequence] - [Control] - [
Recipe finish
action
]
Storing the time of mixture
[5q f-47]
[Function] - [Function setting] - [Sequence] - [Timer] - [
Mixing time output
on
]
Safety check during mixture
[5q f-74]
[Function] - [Function setting] - [Sequence] - [Safety] - [
Mixing safety
check
]
Advise
Safety check during mixture
When the specified input terminals at [5q f-74] are all ON, it supposes that the
sequence is safety and is continued. If a terminal of them is OFF, an error code is
output and sequence is stopped.