LG Electronics STB-2000 DVR User Manual


 
29
206-4256
Installer Menu (Cont.)
000 - INSTALLER SEQUENCE
SpeciesentrysequencetotheInstallerMenu.
0 = 9876 1 = 4321
2 = 1478 3 = 3698
001 - POWER MANAGE (Power Management)
Determines hours of no activity before automatic shutoff. The
Power Management function is for saving energy. If set to 0,
Power Management is Off. Settings range from 0 ~ 7, with 1 ~ 7
representing the hours that the unit will remain ON, unless there
has been activity from either the control panel or remote control.
002 - AC ON (AC Power Switchable)
If set to 1, this allows the STB/display panel to turn ON when AC
power is applied. Pressing the POWER button is not necessary.
This is desirable if the STB is plugged into a switched AC outlet.
Set to 2 or 3 to enable the Instant ON feature (see additional
information below). Set to 0 (default) for standard STB/display
turn ON/OFF operation.
The Instant ON feature allows the STB to turn ON when AC power
is applied, while the display panel remains OFF. The STB retains
its ON status, and the POWER button only toggles the display On
and Off.
• If this item is set to 2, the STB will reboot to check for and down-
load updates from the Pro:Centric server each time the display
panel is turned OFF. This setting is not recommended if the STB
willbeconguredwitharesidentapplication.
• If this item is set to 3, the STB will not reboot to check for and
download updates each time the display panel is turned OFF.
ThissettingisrecommendediftheSTBwillbeconguredwitha
resident application. In this mode, the check for and download of
updatesisunderapplicationcontrol.Refertoyoursite-specic
documentationforfurtherinformationonconguringtheSTBwith
a resident application.
When this item is set to 2 or 3, the STB will reboot once every 24
hours and, if applicable (i.e., item 119 DATA CHANNEL is set),
check for and download updates from the Pro:Centric server. The
time at which this event occurs depends on the setting of item 121
UPDATE TIME HR. See item 121 description for further information.
Once the update cycle is complete, the STB completes the reboot
and resumes its ON state with the display panel OFF.
Note: If set to 1, the STB does not respond to ON/OFF commands
from the remote, and the SLEEP TIMER is also nonfunctional.
003 - BAND/AFC (Band/Automatic Frequency Control)
There are four possible settings for this option:
0 = Broadcast 1 = CATV (default)
2 = HRC 3 = IRC
If some channels were not found by Auto Tuning (Channel
Search), select the appropriate Band setting here, and add the
channels using the Channel Edit option in the Channel Menu.
004 - STRT CHANNEL (Start Channel)
If active, this function allows you to determine the initial Major
Start Channel number when the STB/display panel is turned
ON. This feature is useful for an in-house information channel,
since the STB/display would always select that channel when it is
turned ON. If set to 255, the last channel tuned before the STB/
display was turned OFF will be the channel tuned when the STB/
display is turned ON again.
0 = Aux 127 = Map to Major CH 4
1 ~ 125 = Major Ch. # 253 = IP Start Channel
126 = Map to Major CH 3 255 = Last Channel
Note: For a digital Start Channel, always remember to set item
104 to the Minor Start Channel number.
Note: 126 and 127 are mapped only in SONIFI PPV Mode.
Note: The IP Start Channel shown above can only be set in the
FTGFileManager,whichisusedtocongureSTBCPUsforFTG
Mode. The same applies for the additional Major Channel number
range of 128 ~ 135 in Physical tuning and 128 ~ 999 in Virtual
tuning mode. This means that these values, if set, will only be
visible in the read-only Installer Menu when the STB is in FTG
Mode. The read-only display also will show additional information
about the channel, for example, the IP address and port number,
etc.
005 - CHAN LOCK (Channel Lock)
Channel Lock is ideal if the system must always be on the same
channel. Changing channels with the Channel Up/Down or keypad
numbers is impossible. Channel Lock is inactive if set to 0 (default).
Generally, this feature is used in connection with item 004 STRT
CHANNEL where the Start Channel may, for example, be set to 3
or 4. If the Start Channel is 3, then the STB will remain locked on
channel 3.
NOTE: For items 007, 008, and 009
For legacy reasons, the scale used is 0 – 63. The PTC software
will translate this to the 0 – 100 scale used by the STB.
To translate an STB volume level to the Installer Menu value,
use the following formula:
Installer Value = STB Value x 63
100
Enter only the whole number (disregard fractions).
007 - STRT VOLUME (Start Volume)
This function allows the Installer to determine the initial volume
level setting when the STB/display panel is turned ON. This feature
is useful for an in-house information channel, since the STB/display
will always select that volume level when it is turned ON. The range
of values is 0 to 63, 255. If set to 255, the last volume level before
the STB/display was turned OFF will be the current volume level
when the STB/display is turned ON again.
Detailed Descriptions of Installer Menu Items