LG Electronics STB-2000 DVR User Manual


 
34
206-4256
Installer Menu (Cont.)
121 - UPDATE TIME HR
Based on the settings of this item and item 122 UPDATE TIME
MN, the Wake For Update feature wakes the STB once daily to
check for and, if applicable, download updates from the Pro:Centric
server.
Set the Wake For Update hour from 0 to 23. This item uses the
24-hour clock format. The value “128” (default) is displayed as
“OFF.” Directly entering 128 resets the default value (OFF) for this
item, though note that this setting does not mean the STB will not
initate update events—see additional information below.
Under standard STB/display panel OFF/ON operating conditions
(i.e., item 002 AC ON is set to 0), a Wake For Update event occurs
when the STB/display is OFF and causes the STB to temporarily
turn ON, perform the update cycle, and then turn back OFF, all
while the display remains OFF. If item 002 AC ON is set to 2 or 3
for Instant ON, then the STB is always ON and Wake For Update
occurs when the display is OFF. The Wake for Update event
causes the STB to reboot in order to perform the update cycle and
then return to its ON state with the display panel OFF. See also
description for item 002.
Random Distribution of Update Time: If this item is set to 128
(OFF), the time at which either a Data Channel Auto Search (item
119 set to 255) and/or an Instant ON update (item 002 set to 2
or 3) occurs is determined as follows: The STB will initiate the
search and/or check for updates during the 2 AM hour (if the STB
clock is set) or after two hours of elapsed time from when AC
power was applied (if the STB clock is not set). The update time
minute is randomly distributed per STB during the hard-coded
hour. That is, each individual STBisassignedaxedupdate
time minute from 0 to 59. (In installations with a large quantity of
STBs, there will be some STBs that have the same update minute
assignments.) The update time/assigned update minute for the
STB is displayed at the right of this item in the Installer Menu, for
example:
121 UPDATE TIME HR OFF 02:34
If the display is ON when a Wake For Update is to occur, the
update will take place the next time the display is turned OFF.
Note: This item is not available in the Installer Menu when item
119 DATA CHANNEL is set to 0, except when item 002 AC ON is
set to 2 for Instant ON.
Note: The STB clock must be set in order for a Wake For Update
event to occur at the precise time of day in accordance with item
121 and item 122 settings.
122 - UPDATE TIME MN
Set the Wake For Update minute from 0 to 59. If item 121 is NOT
set to 128 and you wish to invoke the “random” minute assignment
on the STB, set this item to 255. See also description for item 121
UPDATE TIME HR above.
Note: This item is not available in the Installer Menu unless item
121 UPDATE TIME HR is set from 0 to 23.
Note: The STB clock must be set in order for a Wake For Update
event to occur at the precise time of day in accordance with item
121 and item 122 settings.