206-4256
080 - UPN MSB-2 (UPN Most Signicant Byte-2)
Userprogrammablenumber,mostsignicantbyte-2readableby
MPI command. Note: Not linked to serial number.
081 - UPN LSB (UPN Least Signicant Byte)
Userprogrammablenumber,leastsignicantbytereadableby
MPI command. Note: Not linked to serial number.
082 - CHKSM ERROR (Checksum Error)
Enforces rigid MPI checksum validation. Set to 1 for validation.
Set to 0 to disable (does not check checksum on MPI async port).
SPI is always checked.
083 - HANDSHK TIME (Handshake Time)
Adds an additional delay to the handshake time which is 64 msec,
thus relaxing MPI timing requirements to be compatible with PC-
based Windows controlled systems. Range is 0 - 5.
(Timeout = 25.5MS + [25.5 MS* Handshake time].)
084 - PERMANENT BLK (Permanent Block)
Allows Lock (Parental Control) blocking schemes to be permanent
by disabling the blocking hours function. Set to 1 to install Parental
Controlrestrictionspermanently.Setto0foruser-speciedhours
control of blocking schemes.
Note: This item is not available in the Installer Menu when item
021 V-CHIP is set to 0.
086 - V. MUTE TIME (Video Mute Time)
Use to extend the normal video mute time during channel change.
For example, you may wish to extend the normal video mute time
to prevent the display of encrypted video (i.e., from a Pro:Idiom
encrypted channel) that has not yet been decrypted. When set to
0, the normal video mute time is not extended. Set from 1 to 50 to
increase the normal video mute time in 100 ms step increments up
to a maximum of 5 seconds (e.g., the value of 25 represents 2.5
seconds, or 25 x 100 ms = 2.5 seconds).
088 - EN NOISE MUTE (Enable Noise Mute)
Applicable for analog channels only. If set to 1, audio mutes if no
signal is present.
090 - KEY LOCK
Applicable for LG Hospitality and commercial non-LG display
panels only. If set to 1, Key Lock is enabled, which means that all
display panel button functions will be locked, i.e., non-functional.
Set to 0 to disable Key Lock.
Note: This feature does not apply to LG Public Displays or LG
Commercial Monitors since the STB will always disable those
displays’ panel buttons and the processing of IR.
091 - HDMI2 ENABLE
Set to 1 to enable HDMI 2 input in DTV Mode. Set to 2 to enable
HDMI 2 input in PC Mode. Set to 0 to disable display panel HDMI
2 input.
094 - SAP MENU EN (2nd Audio Program)
Set to 1 to enable the SAP feature in the Function Menu, when
the Function Menu is available (i.e., STB is not in Pass-through
Mode). Set to 0 to disable the SAP feature in the Function Menu,
when the Function Menu is available.
096 - DEF. ASP. RATIO (Default Aspect Ratio)
Selects default aspect ratio at power up:
0 = Set By System 1 = 4:3
2 = 16:9 (default) 3 = Just Scan
4 = Zoom
Note: This item is not available in the Installer Menu unless item
106 ASP RATIO LOCK is set to 0.
097 - AUDIO OUTPUT
Determines availability of the analog audio output to be used by
external audio equipment connected to the Audio Line Out jack
on the STB. Set to 0 to disable audio output. Set to 9 (default) to
enablexedlinelevel(typically400mVrms±100mVrms@10KΩ)
output. See also Reference section, “External Audio Line Out
Specifications.”
098 - PRO:CENTRIC
Selects the Pro:Centric Application Mode. Set to 0 (default) to
disable the Pro:Centric application. Set to 1 for Flash Mode. Set
to 2 for GEM (Java Application) Mode. Set to 3 for HTML Mode.
In order to retrieve the Pro:Centric application, when enabled (for
Flash, GEM, or HTML Mode), the STB must be turned OFF/ON two
times. Once you exit the Installer Menu, turn OFF the STB/display
panel for at least one minute. When you turn the STB/display back
ON, the STB will start the appropriate library based on the setting
of this item. Wait until TV programming appears on the display, and
then turn the STB/display back OFF, this time for a few minutes, to
initiate the application download. When you turn the STB/display
back ON, press the PORTAL key on the Installer Remote, and
verify that the Pro:Centric application appears on the display.
Note: This item is not available in the Installer Menu when item
119 DATA CHANNEL is set to 0.
100 - VIDEO INTERFAC
Selects the HDMI port on the display panel to be used for HDMI
input from the STB. Set to 3 for HDMI 1 (default). Set to 4 for
HDMI 2. Set to 5 for HDMI 3.
If you change the value of this item, make sure to reconnect the
HDMI cable from the STB to the appropriate HDMI port on the
display panel once you have exited the Installer Menu.
102 - ATSC BAND
Sets up STB to receive different types of incoming signals.
0 = Broadcast 1 = CATV 2 = HRC
3 = IRC 4 = Same as NTSC