Polycom MGC WebCommander Version 9.0 Home Theater Server User Manual


 
Appendix B: Monitoring a Conference in the WebCommander using a URL or Form
B-2
When an incorrect conference password is sent, the user is prompted
for the conference entry password prior to being granted access the
conference.
b. When the user’s permission "Always prompt for conference
password" is not selected, the user enters the conference without
having to enter the conference entry password (and therefore it does
not have to be included in the URL).
2. When the user name (Param2) and password (Param3) are not sent as
part of the URL:
a. The user connects to the conference using the default user name and
password defined in the WebCommander database. If the correct
conference entry password is sent as part of the URL, the user enters
the conference without being prompted.
b. If no conference entry password or an incorrect conference
password is sent, the user is prompted for the conference entry
password regardless of the user’s permission settings for "Always
prompt for conference password" parameter.
URL Format
The URL should be of the following format:
"http://Server name or IP/confsitev8_0/MonitorConf.asp"
In addition, the URL must include the parameters that identify the MCU and
the conference. Additional parameters can also be included. These variables
are described in the Table B-1, "Variable Definitions."
In the http://Server name or IP script you can either include the Server name or
Server IP.
Table B-1: Variable Definitions
Variable Description
Required variables:
ConfId The conference ID.
ConfName The name of the On Going conference.