3 - 12 ONline Ethernet Management Module Installation and Operation Guide
Assigning an EMM Name
To make identification of your EMMs easier, 3Com recommends that you
assign a unique name to each EMM. You can then use this name instead of
the IP address or MAC address to refer to a particular EMM. Use the SET
DEVICE NAME command as shown to assign a unique name to your EMM.
The EMM name can be a maximum of 31 characters.
ONline> set device name EMM3 [ENTER]
3Com recommends that you use the same identification to specify the
terminal prompt and the device name for your EMM.
Setting Device Diagnostics
When the EMM is reset (or rebooted) using the factory default settings, the
module performs a full diagnostic check of itself and then sets all the
modules to the appropriate settings. You have the option to disable the
diagnostics if you want the EMM to boot up faster. Use the SET DEVICE
DIAGNOSTICS command as shown to bypass the diagnostics.
ONline> set device diagnostics disable [ENTER]
Assigning a Contact Name and Location
The EMM enables you to enter the name of an appropriate service contact
and the concentrator location. Use the SET DEVICE LOCATION and SET
DEVICE CONTACT commands as shown to identify the location of the EMM
and the name of the person responsible for EMM operation. These
commands allow you to enter one line of free format text up to 78
alphanumeric characters in length. Note that you must enter the line of text
within 15 seconds of receiving the prompt or the command will timeout.
ONline> set device location [ENTER]
ONline> set device contact [ENTER]