Troubleshooting 4 - 5
EMM Trap Messages
A trap message is sent to the console when a change is made or an error
occurs in a concentrator that has an installed EMM. The trap is also sent to
the designated trap receiver (e.g., management workstation) if you have
entered this information in the EMM community table. For example, if a
module is removed from a concentrator, a message that describes the
change is sent to the console, as shown below:
Message received from this device on 15:28 Mon 09 Aug 93:
Enterprise: Chipcom
Enterprise Specific Trap: Slot Down
Message Information:
Slot Number: 6
Module Type Number: 6
Module Description: 5108M-TP
The Master MGT Module LED
blinks sporadically.
Check for multiple EMMs and verify
that only one has been set to a
mastership level of 10.
The >> prompt appears on the
screen.
The EMM is running in maintenance
mode. Type BOOT to return to
management mode and the ONline>
prompt.
Table 4-2. EMM Terminal Interface Suggestions (Continued)
Problem Troubleshooting Suggestions