3Com 5101M-MGT TV Receiver User Manual


 
5 - 16 ONline Ethernet Management Module Installation and Operation Guide
Note: You can perform an inband download (remotely or locally)
when you are logged into an Advanced EMM. However,
you cannot perform an inband download when you are
remotely logged into either a Starter or Basic EMM. This is
because Starter and Basic EMMs must be in maintenance
mode in order to perform an inband download. When an
EMM enters maintenance mode, a remote session is
disconnected.
The following prerequisites must be completed prior to initializing the
download:
You must have a TFTP server on the network to perform inband
downloads
EMMs to be updated must be assigned to the same network as the
TFTP server
Use the following procedure to perform an inband download to a Starter,
Basic, or Advanced EMM. Additional steps required to perform a download
from maintenance mode are included.
1. Transfer the contents of the UDK floppy disk to your network TFTP
server using the copy command for DOS-based systems. Use the FTP
BINARY mode for UNIX-based systems. Note that the FTP BINARY
mode must be specified instead of the default ASCII mode or the file
will be corrupted.
Note: If your TFTP server is running on a UNIX machine, you need
to FTP the file from the DOS machine to the server. If your
server is running in a DOS environment, you must be in the
directory that contains the.BIN file when you start the
server.
The floppy disk contains one file - emm400.bin, which updates the
Flash EPROM.