Startup and Management Functions 3 - 19
Note: When you power up a concentrator in which more than
one management modules is set to priority level 10, one
management module is randomly chosen as master. 3Com
recommends that you assign priority level 10 to only one
management module in the concentrator.
Setting Port Mode
Use the SET PORT command to enable port 1 on the module in slot 3:
ONline> set port 3.1 mode enable [ENTER]
Setting Port Network
Use the SET PORT NETWORK command to assign a port to a specific
network. This command applies to 3Com modules (e.g., the ONline
Ethernet Bridge Module) where individual ports are network-selectable.
This example assigns port 1 on the module in slot 7 to network ethernet_3.
ONline> set port 7.1 network ethernet_3 [ENTER]
Setting Redundant Ports
Use the SET PORT MODE REDUNDANT command as shown to set
redundancy between port 1 on the module in slot 5 to port 2 on the
module in slot 7.
ONline> set port 5.1 mode redundant 7.2 [ENTER]