Polycom RMX 1800 Home Theater Server User Manual


 
Polycom® RMX 1800 Administrator’s Guide
20-20 Polycom, Inc.
4 Click OK to close the New Flag dialog box.
The new flag is added to the flags list.
5 Click OK to close the System Flags dialog box.
Manually Adding Flags to the CS_MODULE_PARAMETERS Tab
Using the procedure to manually add flags to the System Configuration, the following flags
can be manually added to the CS_MODULE_PARAMETERS
tab:
Deleting a Flag
To delete a flag:
1 In the System Flags dialog box, select the flag to delete and click the Delete Flag button.
2 In the confirmation message box, click Yes to confirm.
3 Click OK to close the System Flags dialog box.
WRONG_NUMBER_DIAL_
RETRIES
The number of re-dial attempts for a wrong destination
number or a wrong destination number time-out.
Range: 0 - 5
Default: 3
A flag value of 0 means that no redials are attempted.
Table 20-2 Manually Added System Flags – MCMS_PARAMETERS (Continued)
Flag Description
For flag changes (including deletion) to take effect, reset the MCU. For more information see
"Resetting the Collaboration Server (RMX)” on page 19-54.
Table 20-3 Manually Added Flags - CS_MODULE_PARAMETERS Tab
Flag Description
H323_TIMERS_SE
T_INDEX
Enables or disables H.323 index timer according to standard or proprietary
H.323 protocol.
Possible values:
0 (Default) - Sets the H.323 index timer to Polycom proprietary.
1 - Sets the H.323 index timer based on the H.323 Standard
recommendation.
Note: For homologation and certification testing, this flag must be set to 1.
QOS_IP_SIGNALIN
G
Used to select the priority of IP packets when DiffServ is the is the selected
method for packet priority encoding.
Range: 0x##
Default: 0x28
SIP_TIMERS_SET_
INDEX
SIP Timer type timeout settings according to standard or proprietary
protocol.
Possible values are:
0 - Default
1 - SIP Standard recommendation.
Note: For homologation and certification testing, this flag must be set to 1.