Mitsubishi Electronics MELSEC-F Universal Remote User Manual


 
9 - 10
MELSEC-F
WHEN COMMUNICATING DATA USING THE MC PROTOCOL9
9 - 10
(2) Format when communicating in ASCII code
(a) The order when sending a command (external device Ethernet module)
(b) The order when receiving a response (external device Ethernet module)
30
H
30
H
46
H
46
H
30
H
30
H
30
H
41
H
"0" "0" "F" "F" "0" "0" "0" "A"
(L)(H)(L)(H)
30
H
30
H
38
H
30
H
34
H
36
H
30
H
30
H
30
H
30
H
30
H
30
H
30
H
32
H
44
H
34
H
"0""0""8""0""4""0""0""0""0""0""0""0""2""D""4" "6"
(H) (L) (H) (L)
(H) (L)
(100)
Header
Application data
Subheader PC number
Monitoring timer
(Local station)
(2500 ms)
Application data
Text (command)
(Device name) (Head device number)
Number of
device points
(M)
(8 points)
31
H
30
H
31
H
30
H
M100(ON)
M107(OFF)
M101(OFF)
M102(ON)
M105(ON)
M103(OFF)
M104(OFF)
30
H
30
H
30
H
38
H
30
H
31
H
31
H
30
H
8
M106(ON)
"0" "0"
(H)
"0"
(L)
"1"
(H)
"0" "1" "0" "0" "1" "1" "0"
(L)
Header
Subheader
Complete
(Normal
completion)
Application data
Text (response)
ON/OFF status of the designated device