Mitsubishi Electronics MELSEC-F Universal Remote User Manual


 
5 - 8
MELSEC-F
COMMUNICATION PROCEDURE5
5 - 8
TCP ULP
timer value
TCP end
timer value
=
TCP resend
timer value
=
(Each timer value should be identical.)
(3) When communication errors occur, the setting value should be changed to
increase the number of retries.
The number of retries is obtained by using the following equation:
(In case of the initial values, 2 = (60/20) - 1)
Example: Assuming the values are set in such a way that the number of retries is
two, a data transmission error will occur at the timing shown in the
figure below if data transmission fails (when communicating using fixed
buffer).
(4) Perform the following setting in order to eliminate the retries explained in (3) (i.e.,
to set the number of retries to 0).
(5) The target existence check is a function whereby the Ethernet module checks
whether or not a remote device is functioning normally by sending an existence
check message and then waiting to see whether a response message is
received. It is used if a connection to a remote device is open but communication
with the remote device has not been performed for a certain period of time.
(a) The existence check function has two methods of checking: PING and
KeepAlive.
The Ethernet module performs each of the existence checks based on the
setting values explained in (7) to (9) of this section and the existence check
setting of the open settings (refer to Section 5.5 (6)).
The existence check function (Ping or KeepAlive) can be selected at the time
of operation setting or re-initialization.
For the operation setting, refer to Section 4.6.
Refer to Subsection 5.2.3 for the explanation on re-initialization.
Number
of retries
TCP ULP timer value
TCP resend timer value
-1
R
0002
H
Data
command
Ethernet module
First retry Second retry
AAA
TCP ULP timeout value
A : TCP resend timer value
(The time after which the data should be retransmitted when
an "ACK" is not returned after sending data.)
Transmission request
and status
#1610 to 1617
W
0001
H
R
0008
H
TCP ULP
timer value
TCP end
timer value
=
TCP resend
timer value
=
(Each timer value should be identical.)