Sanyo VA-SW80LITE DVR User Manual


 
32
English
MENU SETTINGS (MENU WINDOW) (User Level: ID4)
5
ALARM MODE (Default setting: OFF)
This sets the recording mode for alarm
recording. Make the selection from the
drop-down list box and then click [APPLY].
Available settings:
OFF: Alarm recording is not carried out.
ENABLED: Alarm recording is always
carried out regardless of the timer
recording settings.
AL-REC ON TIMER: Alarm recording is
only carried out while timer recording is in
progress.
AL-REC OFF TIMER: Alarm recording is
only carried out while timer recording is not
in progress.
OLY AL-REC ON TMR: Alarm recording is
carried out during the time specified for
timer recording, and timer recording is not
carried out.
6
ALARM DURATION (Default setting: 20S)
This sets the alarm recording duration when
an alarm occurs. Select the duration from the
drop-down list box and then click [APPLY].
Available settings:
5S, 10S, 20S, 40S, 1M, 2M, 3M, 4M, 5M,
10M, 15M, CC
7
ALARM SENSOR (Default setting: ALARM)
This sets the operating conditions for alarm
recording. Make the selection from the
drop-down list box and then click [APPLY].
Available settings:
ALARM: In response to an external alarm
SENSOR: In response to motion sensor
input
ALARM OR SENSOR: In response to
either an external alarm or motion sensor
input
ALARM AND SENSOR: In response to
both an external alarm and motion sensor
input occurring at the same time
8
VIDEO LOSS (Default setting: ON)
This sets whether a warning is output or not
when the image feed is cut off. Select ON or
OFF and then click [OK] or [APPLY].
Available settings:
Refer to page 17 for explanations of the
setting buttons (CANCEL/APPLY).
ON: A warning is output when the image
feed is cut off.
OFF: No warning is output when the image
feed is cut off.
If you would like the warning buzzer to
sound when the image feed is cut off,
set VIDEO LOSS to ON and then
change the BUZZER setting. (P.37)
