Sony MAV-555SS DVR User Manual


 
Chapter 3 Preparations
3-26 (E) 3-4 Setup
3-4-3 Contents of the Expansion Menu
The contents of the Expansion menu are described in the table that follows.
The item enclosed in a square in the “Settings” column indicates defaults.
The letters “B” and “I” in the item number column indicate when a change to
that setting becomes effective, just as in the Basic menu.
For details on the meaning of each letter, refer to Section 3-4-1, “Basic Menu Settings” (page
3-18).
Expansion menu items
Item number Display indication Settings Description
101
BI
SELECTION FOR SEARCH
DIAL ENABLE
This item sets the method for putting the MAV-555SS into search mode.
dial direct : The unit enters search mode when the search dial is turned from any
mode except while recording/editing are in progress.
: The unit enters search mode when any of the following buttons is
pressed: JOG, SHUTTLE, VAR.
102
BI
SHUTTLE MODE
SYNCHRONIZE
This item specifies the startup characteristics when
entering shuttle mode.
: Normal disk characteristics
mode 2 : Squared acceleration
mode 3 : Linear acceleration
105
B
SYNCHRONIZE This item specifies, for playback and for variable speed playback (JOG/VAR) with
FORT synchronization control, whether to apply speed limitations when reversing the
playback direction or to not apply speed limitations and give priority to response.
: Apply no speed limitations, and give priority to response.
on : Apply speed limitation.
Note: When playing back material recorded in SS mode, this setting reverts to off.
106
BI
MAXIMUM SHUTTLE SPEED This item specifies the maximum shuttle speed.
×8 : Maximum shuttle speed is 8×.
×16 : Maximum shuttle speed is 16×.
: Maximum shuttle speed is 32×.
×50 : Maximum shuttle speed is 50×.
×100 : Maximum shuttle speed is 100×.
×200 : Maximum shuttle speed is 200×.
×500 : Maximum shuttle speed is 500×.
Note: With some editing equipment, if a maximum speed of 100× or greater is set,
the speed is deemed to be impossible for FF or REW, and the TC display
disappears. If using equipment in which this happens, set a speed of less
than 100×.
107
BI
MAXIMUM JOG SPEED Sets the maximum JOG speed.
×1, ×2,
, SHUTTLE
When SHUTTLE is selected, the maximum speed set in SETUP MENU 106 is applied.
Note: This means that synchronization is not possible during linear editing when the
JOG speed is set to ×2 (or greater). For linear editing, set the JOG speed to ×1.
108
BI
AUTO EE SELECT This item sets the conditions for switching to the REC port when PB/EF SELECT (menu
013) is set to PB/EE.
: Switch the PB side to the EE side during STOP/FAST FORWARD/
REWIND.
stop : Switch the PB side to the EE side during STOP.
109
BI
ENFORCED EE INTERFACE Enables the ENFORCED function of the EE command specified from the 9PIN terminal
and meter panel in the Panel mode. This menu setting and the control panel setting
match and determine the ENFORCED EE function from the control panel.
: Enables ENFORCED EE
disable : Ignores the command.
120
I
OUTPUT REF LOCK This item specifies whether to synchronize the output system video refresh with the REF
input jack, the R1 video input jack, or the R2 video input jack.
: Synchronize with the reference video signal input through the REF IN jack.
R1 : Synchronize with the video signal input through R1.
R2 : Synchronize with the video signal input through R2.
Note: When the configuration is 3 input/1 output, the R3 port cannot be specified.
via search key
mode 1v
t
mode 3 mode 2
mode 1
off
×32
×4
stop/f.fwd/rew
enable
REF