Agilent Technologies 16760A TV Converter Box User Manual


 
234
Chapter 5: Reference
Specifications and Characteristics
200 Mb/s Sampling Mode Specifications and
Characteristics
NOTE: All specifications are marked by "*" (asterisk).
Maximum data rate: 200 Mb/s
Minimum clock interval (active edge
to active edge)*: 5 ns
Minimum state clock pulse width: 1.5 ns
Clock periodicity: Periodic or Aperiodic
Number of clocks/qualifiers: 1
Clock polarity: Rising falling or both
Minimum data pulse width: 1.5 ns
Number of Channels
With time tags: 34 x (number of modules)
Without time tags: 34 x (number of modules)
Maximum channels on single time
base and trigger: 180 (5 modules)
Maximum memory depth: 32 M samples
Setup and Hold Time Range
(manual adjustment),
single edge: +4.5 ns / -2.0 ns to -2.0 ns / +4.5 ns
multiple edge: +5.0 ns / -2.0 ns to -1.5 ns / +4.5 ns
Window width (manual adjustment)*,
single edge: 2.5 ns
multiple edge: 3.0 ns
Window width after running eye finder: 1.25 ns
Adjustment resolution: 100 ps
Time tag resolution: 4 ns
Maximum time count between states: 17 sec
Trigger resources: 16 patterns (=,/=,<,>,<=,>=),
15 ranges (in range, not in range),
Timers = (number of pods assigned),
2 global counters,
1 occurrence counter per sequence level,
4 flags
Trigger actions: Go to,
Trigger and Go to,
Trigger and fill memory,
Store/don't store sample,
Turn default storing on/off,
Timer (start,stop,pause,resume),
Global counter increment.reset,
Occurrence counter reset,
Flag set/clear
Maximum trigger sequence levels: 16
Maximum trigger sequencer speed: 200 MHz
Store qualification: Default and per sequence level
Maximum global counter: 16,777,215
Maximum occurrence counter: 16,2777,215
Maximum pattern/range term width: 32 bits
Timer value range: 100 ns to 4397 sec
Timer resolution: 4 ns
Timer accuracy: +/- (10 ns + 0.01% of value)
Timer reset latency: 60 ns
Data in to BNC port out: 150 ns
Flag set/reset to evaluation: 110 ns