WARNUNG Im Innern des Monitors liegt gefährliche Hochspannung an. Falls
Sie unter Hochspannung stehende Teile berühren, können Sie
einen elektrischen Schlag erhalten bzw. Verbrennungen oder
sogar den Tod erleiden. Im Innern befinden sich keine Teile, die
von einem Laien gewartet oder repariert werden könnten.
Überlassen Sie alle Wartungs- und Reparaturarbeiten einem
qualifizierten Techniker.
Temperature and Humidity
The WN-5230-S is designed to operate over an ambient temperature range
of 0° to 35° C (32° to 95° F) and between humidity of 20 to 80 % R.H. non-
condensing.
The air that cools the display and the warm exhaust air is passed through the
back of the WN-5230-S. This area should not be blocked. If the display
becomes overheated, permanent damage to the product may result.
Some types of environmental lighting, such as incandescent, or high intensity
discharge lamps such as metal halide or mercury vapor lamps, create high
temperatures and this can cause excessive heating of the WN-5230-S. The
displays should be positioned far enough away from high-temperature lights
to prevent heat buildup.
Nearby heat sources can cause high operating temperatures in the WN-
5230-S. Minimize the display’s exposure to heating ducts, radiators, or other
external heat sources.
Flooring
A typical WN-5230-S weights approximately 120 lbs. (55 kg). Before
installing the WN-5230-S, determine the structural integrity of the flooring
where it will be used. The floor should be level and strong enough to support
the combined weight of the number of displays and other equipment used in
the installation. Take special care when installing a WN-5230-S in a wall
configuration on a temporary structure such as a stage floor, where the
flooring could bend or collapse under the weight of the installation. The
maximum number of WN-5230-S’s stacked vertically in a wall configuration
resting on a temporary floor should be no more than 4.
Clearance
Normal maintenance, such as lamp and air filter replacement, can be
performed from either the front or rear of the WN-5230-S. However, the units
with Ultra-Thin Mullion screens are serviceable only from the rear. A
minimum of 4 feet of clearance is recommended for easy front access and
for easy rear access a minimum of 3 feet is recommended.