Clarity Visual Systems
September 1999
20
Adjustment Summary
(Viewed from the front)
Rotation
Adjustment Hardware Direction Effect On Image
S1 and S2 together Tighten Right side up
S1 and S2 together Loosen Right side down
S3 and S4 together Tighten Left side up
S3 and S4 together Loosen Left side down
Keystone
Adjustment Hardware Direction Effect On Image
S1 and S3 together Tighten Top wider, Image up
S1 and S3 together Loosen Top narrower, Image down
S2 and S4 together Tighten Bottom wider, Image down
S2 and S4 together Loosen Bottom narrower, Image up
Size
–
(LD1 and LD2 must be loosened before adjusting N1 and N2.)
Adjustment Hardware Direction Effect On Image
N1 and N2 together Tighten Smaller
N1 and N2 together Loosen Bigger
(Retighten LD1 and LD2.)
Final Position
–
Up/Down/Left/Right
Adjustment Hardware Direction Effect On Image
LS1 Tighten Moves left
LS1 Loosen Moves right
LS2 Tighten Moves up
LS2 Loosen Moves down