15. SIEMENS PLC 5-91
Connection to PLCs
S5, S5 V4 (S5-115U, S5-135U, S5-155U, S7-300, S7-400)
S5 PG port
Communication parameters are automatically set.
S7-200PPI
S7-300MPI (HMI ADP), S7-300MPI (PC ADP)
Set [MPI SETTING] in the [Comm. Parameter] dialog of the V-SFT editor.
Set different numbers for [Source No.] and [Local No.], and make sure that [Source No]
[Node Cnt].
[Node Cnt] is equivalent to [Local No.] of the PLC. (For example, if [Local No.] is “13,”
[Node Cnt] is “15.”)
Item Setting on PLC V7 Comm. Parameter Setting
Baud rate 9600 bps 9600 bps
Parity Even (fixed)
Transmission code
Data length 8 (fixed)
Stop bit 1 (fixed)
Item Setting on PLC V7 Comm. Parameter Setting
Baud rate 9600 bps 9600 bps
Port 2 2
Parity Even (fixed)
Item Setting on PLC V7 Comm. Parameter Setting
Baud rate 38400 bps
HMI ADP 38400 bps (fixed)
PC ADP 38400 bps
Parity Odd (fixed)
Transmission code
Data length 8 (fixed)
Stop bit 1 (fixed)
Local No. (PLC port number) 2 2
Item MPI SETTING
Node Cnt 15/31/63/126
Source No. (V7 port number) 0