Setting Up for Notification of Storage Problems
The DVR can be set to react to storage problems by:
• activating an internal buzzer or external alarms
• displaying a warning message
• and/or notifying a PC that is running RASplus (Remote Administration System)
1. Highlight the field beside Storage Problem Action: Alarm Out/Notify and press
. A window appears from which you choose the Alarm Out/Notify action(s).
2. Highlight the box beside the desired Alarm Out/Notify action and press to
select the Alarm Out/Notify action you want triggered if there is a storage problem
event. You can choose to activate the alarm output terminals, Beep, and/or
Notify.
3. Select Close and press to save the settings.
Setting the Self-Monitoring, Analysis and Reporting Technology
(
S.M.A.R.T)
Highlight the S.M.A.R.T. Setup… and press . The S.M.A.R.T. Setup screen
appears.
Note If no hard disk drives are installed in the DVR, the S.M.A.R.T.
Setup… button is disabled.
Table 3-4 Storage Screen Setup Fields
Field Information
Type The Type field displays the type and capacity of the storage device.
Status The Status field displays the device status or default conditions. (Good,
Disk Bad, S.M.A.R.T. Alert, High Temperature, or Not
installed).
Note If the DVR senses S.M.A.R.T. Alert or High Temperature, the S.M.A.R.T.
Monitoring Information screen appears. If the S.M.A.R.T. Monitoring
Information screen appears, replace the hard disk drive, preferably within 24
hours.
Note The S.M.A.R.T. Monitoring Information screen appears only in the monitoring
mode.
°C The °C field displays the temperature of the storage device.
Usage The Usage field displays the device usage.