11. OUTLINE
Size 2200 mm (88 in.) to 2600 mm (104 in.)
2.4
2.0
1.6
1.2
0.85
0.8
0.4
0
012 6810
V[m/s]
F16-3.EPS
Pulse
Output
Accuracy
% of Rate
High grade Accuracy
High grade Accuracy
Standard Accuracy
Current Output:
Pulse output accuracy plus Ϯ0.05% of Span
Repeatability:
Ϯ0.1% of Rate (V м 1 m/s (3.3 ft/s))
Ϯ0.05% of Rate Ϯ0.5 mm/s (V < 1 m/s (3.3 ft/s))
Maximum Power Consumption:
Combined with AXF Remote Flowtube: 20 W
Insulation Resistance(*1) :
Between power supply terminals and ground
terminal: 100M at 500V DC
Between power supply terminals and input/output/
excitation current terminals : 100M at 500V DC
Between ground terminal and input/output/excitation
current terminals: 20M at 100V DC
Between input/output/excitation current terminal: 20M
at 100V DC
Withstand Voltage(*1) :
Between power supply terminals and ground terminal:
1390V AC for 2 seconds
Between power supply terminals and input/output
terminals: 1390V AC for 2 seconds
Between excitation current terminal and ground
terminal: 160V AC for 2 seconds
Between excitation current terminal and input /output
terminals: 200V AC for 2 seconds
CAUTION
*1:When performing the Insulation Resistance Test or the
Withstand Voltage Test, please obey the following
caution.
• Following the relevant test, wait for more than 10
seconds after the power supply has been turned off
before removing the cover.
Remove all wires from terminals before testing.
When the power terminal has a lighting protector
(optional code A), remove the short bar at the ground
terminal.
After testing, be sure to discharge by using a resistance
and return all wires and the short bar to its correct
position.
Screws must be tightened to a torque of 1.18 N-m or
more.
After closing the cover, the power supply can be
restored.
Safety Requirement Standards:
EN61010-1
Altitude at installation site: Max. 2000 m above sea level
Installation category based on IEC1010:
Overvoltage category II (“II” applies to electrical equip-
ment which is supplied from a fixed installation-like
distribution board.)
• Pollution degree based on IEC1010
Pollution degree 2 (“Pollution degree” describes the
degree to which a solid, liquid, or gas which deteriorates
dielectric strength or surface resistivity is adhering. “2”
applies to a normal indoor atmosphere.)
EMC Conformity Standards:
EN61326
EN61000-3-2, EN61000-3-3
AS/NZS CISPR11
NORMAL OPERATING CONDITIONS
Ambient Temperature: –40°C to +60°C (–40°F to +140°F)
Indicator’s operating range: –20°C to +60°C (–4°F to +140°F)
Ambient Humidity: 0 to 100%
Lengthy continuous operation at 95% or more is not
recommended.
Power Supply:
Power supply code 1:
AC specifications
Rated power supply: 100 to 240 V AC, 50/60 Hz
(Operating voltage range: 80 to 264 V AC)
DC specifications
Rated power supply: 100 to 120 V DC
(Operating voltage range: 90 to 130 V DC)
Power supply code 2:
AC specifications
Rated power supply: 24 V AC, 50/60 Hz
(Operating voltage range: 20.4 to 28.8 V AC)
DC specifications
Rated power supply: 24 V DC
(Operating voltage range: 20.4 to 28.8 V DC)
Supplied Power and
Cable Length for Power Supply Code 2
0
20.4 22 24 26 28.8
100 ( 330)
200 ( 660)
280 ( 920)
420 (1380)
F00.EPS
Cable cross section area: 1.25 mm
2
Cable cross section area: 2 mm
2
Allowable cable length m(ft)
Usable range E (V)
Vibration Conditions:
Level of vibration in conformity with IEC 60068-2-6
(SAMA31. 1-1980)
0.5 G or less (frequency 500 Hz or less)
Note: Avoid locations with much vibration (with a vibration
frequency of 500 Hz or more), which may cause
damage to the equipment.