Define a sequential function chart routine Chapter 10
Rockwell Automation Publication 1756-RM084S-EN-P - March 2015 201
IndicatorTag := "")
BODY (LanguageType := ST)
'
END_BODY
END_ACTION
ACTION (ID := 27, Operand := Action_000, Qualifier
:= R, IsBoolean := No,
PresetUsesExpression := No, IndicatorTag := "")
BODY (LanguageType := ST)
'
END_BODY
END_ACTION
ACTION (ID := 28, Operand := Action_001, Qualifier
:= N, IsBoolean := No,
PresetUsesExpression := No, IndicatorTag :=
Aliased_Indicator)
BODY (LanguageType := ST)
'
END_BODY
END_ACTION
ACTION (ID := 29, Operand := Action_002, Qualifier
:= DS, IsBoolean := Yes,
PresetUsesExpression := No, IndicatorTag := "")
END_ACTION
ACTION (ID := 30, Operand := ConsumedTag_Action,
Qualifier := P0,
IsBoolean := No, PresetUsesExpression := No,
IndicatorTag := ConsumedTag_Indicator)
BODY (LanguageType := ST)
'
END_BODY
END_ACTION
END_STEP
STEP (ID := 31, X := 120, Y := 880, Operand :=
"C_Array_Step[0,1,2]",
HideDescription := Yes, DescriptionX := 179,
DescriptionY := 865,
DescriptionWidth := 0, InitialStep := No,
PresetUsesExpression := No,
LimitHighUsesExpression := No,
LimitLowUsesExpression := No, ShowActions := Yes)
END_STEP
TRANSITION (ID := 33, X := 460, Y := 1000, Operand :=
NoTag_Tran,
HideDescription := Yes, DescriptionX := 495,
DescriptionY := 985,
DescriptionWidth := 0)
CONDITION (LanguageType := ST)
'TempTag > 0
END_CONDITION