JVC BR-D95U VCR User Manual


 
96
TCR 00:00:00:00
M
H
F
S
CONDITION
TC
UB
To display selected time data on the counter display and the on-screen display
during playback or recording.
Set the COUNTER switch to TC or UB.
Set the counter to the Time Code Display mode with the [COUNTER] button.
Press the [COUNTER] button while pressing the [SHIFT] button to set the
counter to the User Bits Display mode.
“TC” or “UB” is shown on the display depending on the setting.
TC: Displays time code data.
UB: Displays user bits.
10 HOW TO USE TIME CODE
10-1 TIME CODE DISPLAY
Time codes and user bits can be recorded and played back as time data.
The time code area on the tape is divided into the main time code sector used for time data for editing and the sub
time code sector which can be used for optional recording of time code.
Notes
On-screen display data are
output through the rear
panel [LINE2-SUPER]
connector.
(When the [ON SCREEN]
switch on the sub panel is
set to ON.)
The on-screen display
position can be moved with
menu switches No. 501
and 502.
Time code mode display
SUB: Sub time code
Sub time code data display
Sub time code, marked with “SUB”, is
displayed with the main time code on the
on-screen display.
Sub time code is shown when:
• Sub time code is output through the
VITC output (with menu switch No. 504
<INFORMATION SELECT> set to
“TIME+SUB TC (3)” or “TIME+SUB
TC+MODE (4)”).
SUB TCR 00:00:00:00
TCR 00:00:00:00
Time code reader data
display during slow play of
±1.0 times normal or
slower
1st field or 2nd field is
shown.
TC1: 1st field
TC2: 2nd field
User bits
User bits are provided to
allow user-specified data to
be included in the time code
data. User bits are recorded
and played back with the
time code.
User user bits can be preset,
recorded, played back, and
displayed.
The user bits set for each
VCR can be recorded at all
times (UB PRESET AUTO).
•However, you cannot set
sub time code user bits.
TCR :Time code reader data (see the
left column)
TCG :Time code generator data
UBR :User bits reader data
UBG :User bits generator data
TCR • :CTL (control) signal interpo-
lation mark
Hour Second
FrameMinute
POWER
ON
I
OFF
O
M
H
F
S
REC
MENU
PLAY
PAUSE/ STILL
REW
STOP
FF
EJECT
PHONES
CH1
CH2
CH3
CH4
REC
PLAY
PULL FOR VARIABLE
TRACKING
CH1
CH1
CH2
CH3
CH4/
TRACKING
SET
HOLD
PB
PB/EE
COUNTER
UB
CONDITION
AUDIO
INPUT
VIDEO
INPUT
AUDIO
MONITOR
PULL
RELEASE
RESET
VCON
REMOTE
TOP VIDEO AUDIO
OTHERSON SCREENTIME CODESERVO/SYS
USER
INSERT
STAND BY
PLAYER
SEARCH
VAR
P.PLAY
DA3
DA2
DA1VIDEO
ASSEM
IN
ENTRY
OUT
CANCEL
SHIFT
REVIEW
METER MODE
TRACKING
FINE
PREVIEW
AUTO EDIT
PREROLL
TC
RECORDER
DA4
VIDEO CASSETTE RECORDER
BR-D95U
STILL
X-1
REV
FWD
X1
CH2
CH3
CH4
CH1
CH2
CH3
CH4
CH1
CH2
CH3
CH4
SIF
SDI
AES/EBU
AUDIO INPUT / AUDIO MONITOR SELECT
LINE
CPN
L
ANALOG
R
PULL
RELEASE
CTL
P.READ
AUTO
OFF
V.VAR
REMOTE
PB/EE
16:9
TC
UB
DF
SERVO
GENCF
AP
525
OVER
–60
–2
–4
+2
+4
0
–40
–30
–20
–10
0
dB
dB
R
P
OVER
–60
–2
–4
+2
+4
0
–40
–30
–20
–10
0
dB
dB
R
P
OVER
–60
–2
–4
+2
+4
0
–40
–30
–20
–10
0
dB
dB
R
P
OVER
–60
–2
–4
+2
+4
0
–40
–30
–20
–10
0
dB
dB
R
P
625
Variable Motion
COMPONENT DIGITAL
[SHIFT] button
[TC] indicator [UB] indicator
[COUNTER] button
: Non-drop
. Drop frame
....
....
97
10 HOW TO USE TIME CODE
10-2 TIME CODE INITIAL SETTING (PRESET)
The BR-D95U includes a built-in time code generator so that initial values can be set as desired for the time code
and user bits.
User bit data is stored in the built-in nonvolatile memory and retained even when the power is turned off. The
stored data can be preferentially recorded on the tape for editing (UB auto preset function).
Drop Frame/Non-Drop
Frame mode (NTSC only)
In the NTSC system, the
actual number of frames
per second is approxi-
mately 29.97. However,
the number of frames used
by the time code process-
ing standard is 30. To
compensate for this
difference, the Drop Frame
mode drops the 00 frame
and the 01 frame once
every minute (except the
tenth minute). In the Non-
Drop Frame mode, no
frames are dropped and
the difference between
actual tape time and the
time code is ignored.
In the Drop Frame mode,
the front panel [DF]
indicator lights.
Setting
Front sub panel switches for time code setting
Set the [PRESET/REGEN] switch to “PRESET”.
Set the [REC/FREE] switch as desired.
REC: Time code preset in the time code generator runs in the Record mode.
FREE: Time code runs from the preset point in the time code generator.
Set the [INT/EXT] switch to “INT”.
Set the [DF/NDF] switch as desired. (NTSC only):
DROP (0) :Sets the Running mode of the built-in time code generator to
the Drop Frame mode.
NON DROP (1) :Sets the Running mode of the built-in time code generator to
the NON Drop Frame mode.
Front panel setting
Select the Counter Display mode to TC or UB.
Menu switch setting
Menu switch No. 457 <UB PRESET AUTO> setting
When user bit data is preset from the 9-pin remote controller, set this to “OFF”.
When this is set to “ON”, user bit preset data from the 9-pin remote controller is
ignored.
Front sub panel
POWER
ON
I
OFF
O
CH1
AUDIO
INPUT
VIDEO
INPUT
AUDIO
MONITOR
VIDEO CASSETTE RECORDER
BR-D95U
CH2
CH3
CH4
CH1
CH2
CH3
CH4
CH1
CH2
CH3
CH4
SIF
SDI
AES/EBU
AUDIO INPUT / AUDIO MONITOR SELECT
LINE
CPN
L
ANALOG
R
SERVICE USE ONLY
TIME CDOE
INTDF
FREE
PRESET
EXTNDF
REC
REGEN
Variable Motion
COMPONENT DIGITAL
OFF
RF
HID GND
8
ON
ON
4
OFF
TIME CDOE
INT
FREE
PRESET
EXT
DF
NDF
REC
REGEN
ON SCREENCF
(625)