102
10-5 SUB TIME CODE RECORDING AND PLAYBACK
10 HOW TO USE TIME CODE
Notes
● When menu switch No. 450
<SUB TC<VITC> REC> is
set to “ON (1)”
The sub time code is
regenerated with the VITC
signal superimposed on the
video signal from the
[VIDEO IN] connector.
●[TC OUT] connector output
No sub time code data is
output through the rear
panel [TC OUT] connector.
Only main time code (LTC)
is output from the built-in
time code reader.
Time Code Signal Flow
Time code data flow depends on the setting of the menu switch or the [INT/EXT]
switch.
Use this as a reference for switch setting.
Recording sub time code
● In the sub time code sector, you can record either the same data as in the main
time code or the VITC time code received through the [VIDEO IN] connector.
1. Select data to be recorded on the sub time code.
● Menu switch No. 450 <SUB TC (VITC) REC>
OFF (0): “00:00:00:00” is always recorded on the sub time code.
ON (1): Records the VITC received from the [VIDEO IN] connector on the
sub time code.
Initial setting: ON (1)
2. Record the sub time code.
Press the [PLAY] button while pressing the [REC] button.
The selected time code will be recorded.
Play back the sub time code.
● Sub time code data is output through the [VIDEO OUT] connector as a VITC time
code signal superimposed on the video signal.
1. Enable sub time code playback.
● Set menu switch No. 451 <VITC OUTSEL> to “SUB TC (0)”.
Factory setting: TC (1)
2. Play back the sub time code.
Press the [PLAY] button.
[Sub time code data is output through the [VIDEO OUT] connector as a VITC
time code signal superimposed on the video signal.
Sub time code data (indicated with SUB) is shown with the main time code
on the on-screen display (with menu switch No. 504 <INFORMATION
SELECT> set to “TIME+SUB TC (3)” or “TIME+SUB TC+MODE (4)”).
In addition to the main time code used for editing, this unit can also record (and play back) an optional sub time
code in the time code data area on the tape.
TC IN
VIDEO IN
(LINE /
COMPONENT/
SERIAL V/A)
TC OUT
LINE OUT
Internal time code
generator
Main time
code domain
Sub time
code domain
Menu switch No.450
<SUB TC (VITC) REC>
Menu switch No.451
<VITC OUT SELECT>
INT/EXT switch
INT
EXT
OFF
ON
TC
SUB TC
Recording area
Recording
system
Playback system
00:00:00:00
Menu switch No.409
<EXT REGEN TC>
VITC
LTC
103
● Set the switches on the BR-D95U (recording VCR) as follows.
Front panel switch setting
● [INT/EXT] switch: Set to “INT”.
● [REC/FREE] switch: Set to “FREE”.
● [PRESET/REGEN] switch: Set to “PRESET”.
● Set the menu switches as required.
● When menu switch No. 457 <UB PRESET AUTO> is set to “ON (1)”, the user
bit data stored in memory is recorded.
● Send an external sync signal to the [VIDEO REF IN]
connector for editing.
Deliver a black burst or a standard color signal as an external sync signal.
10-6 TIME CODE SWITCH SETTING FOR EDITING
10 HOW TO USE TIME CODE
Note
If there is no external sync
signal generator available,
send a video input signal to
the [VIDEO REF IN] connector
on the recording VCR.
POWER
ON
I
OFF
O
CH1
AUDIO
INPUT
VIDEO
INPUT
AUDIO
MONITOR
VIDEO CASSETTE RECORDER
BR-D95U
CH2
CH3
CH4
CH1
CH2
CH3
CH4
CH1
CH2
CH3
CH4
SIF
SDI
AES/EBU
AUDIO INPUT / AUDIO MONITOR SELECT
LINE
CPN
L
ANALOG
R
SERVICE USE ONLY
TIME CDOE
INTDF
FREE
PRESET
EXTNDF
REC
REGEN
Variable Motion
COMPONENT DIGITAL
OFF
RF
HID GND
8
ON
ON
4
OFF
TIME CDOE
INT
FREE
PRESET
EXT
DF
NDF
REC
REGEN
ON SCREENCF
(625)
Front sub panel