JVC BR-D95U VCR User Manual


 
98
10-2 TIME CODE INITIAL SETTING (PRESET)
10 HOW TO USE TIME CODE
Procedure
1. Engage the Time Code Generator Preset mode.
Press the [HOLD] button.
[The first digit on the counter display blinks.
2. Set the value for the blinking digit by turning
the jog dial while pressing the [SEARCH]
button.
[The value of the blinking digit changes. Use the
hexadecimal (0-9, A-F) for user bits.
3. Shift the digit by turning the jog dial.
[The blinking digits shift to the next one.
4. Set desired values for all digits.
Repeat steps 2 - 3.
5. Presetting is completed by pressing the [SET]
button.
[The selected data are preset in the built-in time
code generator. When preset is finished, the
normal on-screen and counter displays are
restored.
The user bit data is stored in the built-in memory.
Checking the values set in the time code
generator
Procedure
(Do this with the tape unloaded or in the Stop mode)
1. Press the [REC] button to show the value set in
the time code generator.
To check the user bit data stored in the built-in
memory, set the counter display mode to “UB” and
menu switch No. 457 <UB PRESET AUTO> to
“ON (1)”.
2. Pressing the [STOP] button restores the
normal display mode.
M
H
F
S
M
H
F
S
M
H
F
S
M
H
F
S
M
H
F
S
M
H
F
S
POWER
ON I
OFF
O
M
H
F
S
REC
MENU
PLAY
PAUSE/ STILL
REW
STOP
FF
EJECT
PHONES
CH1
CH2
CH3
CH4
REC
PLAY
PULL FOR VARIABLE
TRACKING
CH1
CH1
CH2
CH3
CH4/
TRACKING
SET
HOLD
PB
PB/EE
COUNTER
UB
CONDITION
AUDIO
INPUT
VIDEO
INPUT
AUDIO
MONITOR
PULL
RELEASE
RESET
VCON
REMOTE
TOP VIDEO AUDIO
OTHERSON SCREENTIME CODESERVO/SYS
USER
INSERT
STAND BY
PLAYER
SEARCH
VAR
P.PLAY
DA3
DA2
DA1VIDEO
ASSEM
IN
ENTRY
OUT
CANCEL
SHIFT
REVIEW
METER MODE
TRACKING
FINE
PREVIEW
AUTO EDIT
PREROLL
TC
RECORDER
DA4
VIDEO CASSETTE RECORDER
BR-D95U
STILL
X-1
REV
FWD
X1
CH2
CH3
CH4
CH1
CH2
CH3
CH4
CH1
CH2
CH3
CH4
SIF
SDI
AES/EBU
AUDIO INPUT / AUDIO MONITOR SELECT
LINE
CPN
L
ANALOG
R
PULL
RELEASE
CTL
P.READ
AUTO
OFF
V.VAR
REMOTE
PB/EE
16:9
TC
UB
DF
SERVO
GENCF
AP
525
OVER
–60
–2
–4
+2
+4
0
–40
–30
–20
–10
0
dB
dB
R
P
OVER
–60
–2
–4
+2
+4
0
–40
–30
–20
–10
0
dB
dB
R
P
OVER
–60
–2
–4
+2
+4
0
–40
–30
–20
–10
0
dB
dB
R
P
OVER
–60
–2
–4
+2
+4
0
–40
–30
–20
–10
0
dB
dB
R
P
625
Variable Motion
COMPONENT DIGITAL
[REC] button [STOP] button
[HOLD] button[SET] button
Jog dial
[SEARCH] button
Notes
To cancel a setting, press
the [HOLD] button before
the [SET] button has been
pressed.
In the preset mode (steps
1 to 4), press the [RESET]
button to set all digits to
“0”.
Time code data starts
running as soon as
presetting is finished if the
front sub panel [FREE/
REC] switch is set to
“FREE”.
99
10-3 TIME CODE RECORDING
There are two different ways of recording time code or user bits; recording the data output from the built-in time
code generator and recording externally generated time code or user bits.
The user bit auto preset function allows preferential recording of data stored in the built-in nonvolatile memory.
10 HOW TO USE TIME CODE
Recording time code data output from the built-in time code generator
POWER
ON
I
OFF
O
CH1
AUDIO
INPUT
VIDEO
INPUT
AUDIO
MONITOR
VIDEO CASSETTE RECORDER
BR-D95U
CH2
CH3
CH4
CH1
CH2
CH3
CH4
CH1
CH2
CH3
CH4
SIF
SDI
AES/EBU
AUDIO INPUT / AUDIO MONITOR SELECT
LINE
CPN
L
ANALOG
R
SERVICE USE ONLY
TIME CDOE
INTDF
FREE
PRESET
EXTNDF
REC
REGEN
Variable Motion
COMPONENT DIGITAL
OFF
RF
HID GND
8
ON
ON
4
OFF
TIME CDOE
INT
FREE
PRESET
EXT
DF
NDF
REC
REGEN
ON SCREENCF
(625)
Front sub panel
Menu switch setting
Menu switch No. 403 <REGEN MODE>: Set as desired in the Regen mode.
Menu switch No. 450 <SUB TC (VITC) REC>
When set to OFF (0): “00:00:00:00” is always recorded on the sub time code.
When set to ON (1): Input VITC is recorded in the sub time code.
Factory setting: ON (1)
Setting of menu switch No. 457 <UB PRESET AUTO>
OFF (0): The user bit auto preset function is disabled. The user bit data from
the built-in time code generator is recorded.
ON (1): The user bit auto preset function is enabled. The user bit data stored
in the built-in memory is recorded.
Procedure
1. Press the [REC] button in the Stop mode and check the value of the built-
in time code generator.
[The data value stays on display when the [REC] button is pressed.
Press the [STOP] button to restore the normal display mode.
2. Record the time code and user bits.
[Press the [PLAY] button while pressing the [REC] button.
TCG or UBG is shown on the on-screen counter display.
3. To stop recording, press the [STOP] button.
Setting
Front sub panel switch setting
Contents of
the time code
“REC” or
“FREE”
Switch setting
[INT/EXT]
[REC/FREE] [PRESET/REGEN]
“INT”
“PRESET”
Time code preset in the
built-in time code
generator is recorded.
Recorded in sync
with the time code
recorded on the tape.
“INT”
“REGEN”
“REC” or
“FREE”
Auto regeneration mode
during editing
Use menu switch No.
410 <AUTO REGEN
MODE> to enable time
code regeneration during
editing even with the
[PRESET/REGEN]
switch set to “PRESET”.
To copy VITC when
SDTI signals are input to
the BR-D95U, both the
[SERIAL] connectors
and [TIME CODE]
connectors must be
connected.