JVC BR-D95U VCR User Manual


 
100
10-3 TIME CODE RECORDING
10 HOW TO USE TIME CODE
Front sub panel
Notes
Drop/Non-drop Frame
mode selection (NTSC
only)
Automatically selected
according to the mode of
the received time code
(Drop Frame or Non-drop
Frame).
Regeneration operation
•When time code is being
regenerated with input
time code, the built-in time
code generator stops
counting when no time
code is input.
In the Play mode, time
code regeneration is based
on the playback time code
value.
Inserting time code
If only time code data is
being inserted, record it on
the main time code. It is not
possible to insert it in the
sub time code.
1. Front sub panel switch setting
Select the External Time Code Generator mode by setting the [INT/EXT]
switch to “EXT”.
The [FREE/REC] and [PRESET/REGEN] switch settings are not necessary.
Select the Counter Display or On-screen Display mode to TC or UB with the
[COUNTER] and [SHIFT] buttons.
2. Menu switch setting
Select the external time code to be regenerated.
Menu switch No. 409 <EXT REGEN TC> (Initial setting: LTC (0))
LTC (0): Regenerates the LTC time code input through the rear panel
[TC IN] connector.
Input LTC time code should be regenerated (matched in
terms of sync and phase) with video signals. Make sure you
input an external sync signal to the feeding equipment.
VITC (1): Regenerates the VITC time code superimposed on the video
signal input through the rear panel VIDEO IN connector.
User bit data selection
Menu switch No. 457 <UB PRESET AUTO> (initial setting OFF (0))
OFF (0): User bits regenerated by the time code generator of this unit is
recorded.
ON (1): The user bit auto preset function is activated and the user bit
data stored in the built-in memory is recorded.
Select the sub time code.
Menu switch No. 450 <SUB TC (VITC) REC> (Initial setting: ON(1))
OFF (0): “00:00:00:00” is always recorded on the sub time code.
ON (1): Records the input VITC time code in the sub time code.
3. Record the time code.
Press the [PLAY] button while pressing the [REC] button.
[The selected time code will be recorded.
Recording the time code data output from the external time code generator
Externally generated time code can be recorded after being regenerated with the
time code data output from the built-in time code generator.
POWER
ON
I
OFF
O
CH1
AUDIO
INPUT
VIDEO
INPUT
AUDIO
MONITOR
VIDEO CASSETTE RECORDER
BR-D95U
CH2
CH3
CH4
CH1
CH2
CH3
CH4
CH1
CH2
CH3
CH4
SIF
SDI
AES/EBU
AUDIO INPUT / AUDIO MONITOR SELECT
LINE
CPN
L
ANALOG
R
SERVICE USE ONLY
TIME CDOE
INTDF
FREE
PRESET
EXTNDF
REC
REGEN
Variable Motion
COMPONENT DIGITAL
OFF
RF
HID GND
8
ON
ON
4
OFF
TIME CDOE
INT
FREE
PRESET
EXT
DF
NDF
REC
REGEN
ON SCREENCF
(625)
101
10-4 TIME CODE PLAYBACK
10 HOW TO USE TIME CODE
Time code is output through the rear panel [TC OUT] and [VIDEO OUT] connectors during playback. VITC time
code with the time code data superimposed on the video signal is output through the [VIDEO OUT-LINE] connector.
Sub time code is output through the [VIDEO OUT-LINE] connector as VITC time code when menu switch No. 451
<VITC OUT SELECT> is set to “SUB TC”. Only the main time code is output through the [TC OUT] connector.
Setting
1. Front panel switch setting
Select a Counter Display mode to TC or UB with the [COUNTER] and [SHIFT]
buttons.
2. Menu switch setting
For VITC time code output, select a line to be added to the video signal.
Menu switch No. 400 <VITC LINE-1 SELECT>
(Initial setting: NTSC 16 LINE/PAL 19 LINE)
Menu switch No. 401 <VITC LINE-2 SELECT>
(Initial setting: NTSC 18 LINE/PAL 21 LINE )
Select VITC time code output through the [VIDEO OUT] connector.
Menu switch No. 451 <VITC OUT SELECT>
SUB TC (0) :Outputs the VITC time code recorded in the sub time code.
TC (1) :Outputs the time code recorded in the main time code.
OFF :VITC time code is not output from the [VIDEO OUT]
connector.
Factory setting :TC (1)
Select the Time Code Output mode during search.
Menu switch No. 452 <SEARCH LTC>
OFF (0) :Outputs time code through the [TC OUT] connector during search
at X1.
ON (1) :Outputs time code through the [TC OUT] connector during search
at all speeds. Continuous time code is not available.
3. Play back the time code.
Press the [PLAY] button.
[The selected time code is played back.
TCR or UBR is shown with the on-screen time code data.
LTC time code is output from the [TC OUT] connector.
Main or sub time code selected with menu switch No. 451 <VITC OUT
SELECT> is superimposed on video signals and output to the line selected
with menu switch No. 400 and No. 401 from the [VIDEO OUT] connector.
On-screen display of sub
time code
Sub time code is displayed
with the main time code
when menu switch No. 451
<VITC OUT SELECT>
is set to “SUB TC (0)”.
POWER
ON
I
OFF
O
M
H
F
S
REC
MENU
PLAY
PAUSE/ STILL
REW
STOP
FF
EJECT
PHONES
CH1
CH2
CH3
CH4
REC
PLAY
PULL FOR VARIABLE
TRACKING
CH1
CH1
CH2
CH3
CH4/
TRACKING
SET
HOLD
PB
PB/EE
COUNTER
UB
CONDITION
AUDIO
INPUT
VIDEO
INPUT
AUDIO
MONITOR
PULL
RELEASE
RESET
VCON
REMOTE
TOP VIDEO AUDIO
OTHERSON SCREENTIME CODESERVO/SYS
USER
INSERT
STAND BY
PLAYER
SEARCH
VAR
P.PLAY
DA3
DA2
DA1VIDEO
ASSEM
IN
ENTRY
OUT
CANCEL
SHIFT
REVIEW
METER MODE
TRACKING
FINE
PREVIEW
AUTO EDIT
PREROLL
TC
RECORDER
DA4
VIDEO CASSETTE RECORDER
BR-D95U
STILL
X-1
REV
FWD
X1
CH2
CH3
CH4
CH1
CH2
CH3
CH4
CH1
CH2
CH3
CH4
SIF
SDI
AES/EBU
AUDIO INPUT / AUDIO MONITOR SELECT
LINE
CPN
L
ANALOG
R
PULL
RELEASE
CTL
P.READ
AUTO
OFF
V.VAR
REMOTE
PB/EE
16:9
TC
UB
DF
SERVO
GENCF
AP
525
OVER
–60
–2
–4
+2
+4
0
–40
–30
–20
–10
0
dB
dB
R
P
OVER
–60
–2
–4
+2
+4
0
–40
–30
–20
–10
0
dB
dB
R P
OVER
–60
–2
–4
+2
+4
0
–40
–30
–20
–10
0
dB
dB
R
P
OVER
–60
–2
–4
+2
+4
0
–40
–30
–20
–10
0
dB
dB
R
P
625
Variable Motion
COMPONENT DIGITAL
[PLAY] button
[COUNTER] button
When you are using this
deck as a player, the
recording time code may
not be regenerated when
you output embedded
audio (SERIAL V/A OUT)
signals to the BR-D750U,
BR-D85U or BR-D80U. In
this case, set menu switch
No. 237 <EMBEDDED
AUDIO> to “OFF”.