Chapter 22-System Configuration Flags
Polycom, Inc. 22-39
4 Click OK to close the New Flag dialog box.
The new flag is added to the flags list.
5 Click OK to close the System Flags dialog box.
Manually Adding Flags to the CS_MODULE_PARAMETERS Tab
Using the procedure to manually add flags to the System Configuration, the following flags
can be manually added to the CS_MODULE_PARAMETERS
tab:
WRONG_NUMBER_DIAL_
RETRIES
The number of re-dial attempts for a wrong destination
number or a wrong destination number time-out.
Range: 0 - 5
Default: 3
A flag value of 0 means that no redials are attempted.
Table 22-2 Manually Added System Flags – MCMS_PARAMETERS (Continued)
Flag Description
For flag changes (including deletion) to take effect, reset the MCU. For more information see
"Resetting the RMX” on page 21-69.
Table 22-3 Manually Added Flags - CS_MODULE_PARAMETERS Tab
Flag Description
CS_ENABLE_EPC Add this flag with the value YES (default value is NO) to enable endpoints
that support People+Content and require a different signaling (for example,
FX endpoints) to receive Content.
H245_TUNNELING For use in the Avaya Environment.
In the Avaya Environment, set the flag to YES to ensure that H.245 is
tunneled through H.225. Both H.245 and H.225 will use the same signaling
port.
Default: NO.
H323_RAS_IPV6 If the RMX is configured for IPv4 & IPv6 addressing, RAS (Registration,
Admission, and Status) messages are sent in both IPv4 and IPv6 format. If
the gatekeeper cannot operate in IPv6 addressing mode, registration fails
and endpoints cannot connect using the RMX prefix.
In such cases this System Flag should be set to NO.
Default: YES
H323_TIMERS_SE
T_INDEX
Enables or disables H.323 index timer according to standard or proprietary
H.323 protocol.
Possible values:
0 (Default) - Sets the H.323 index timer to Polycom proprietary.
1 - Sets the H.323 index timer based on the H.323 Standard
recommendation.
Note: For homologation and certification testing, this flag must be set to 1.