To stop motion sensor recording
Press the [MENU] button and select “2.RECORD SET”, “7.
ALARM REC MODE SET”, and “MOTION SENSOR” and
when the motion sensor settings screen appears set “LEVEL”
to “OFF”.
z The sensitivity level can be checked on the setting screen.
When motion is detected, the sensor color changes from
green to red, and a buzzer is sounded.
If detection is too sensitive, an alarm can be triggered even
by slight changes in lighting; accordingly, the sensitivity
level should be set to match the camera location.
z The period for “T-1” through “T-4” as set in step 12
changes to that of “TIME PERIOD A” or “TIME PERIOD B”
on the <TIME PERIOD SET> screen.
Use the following procedure to display the main monitor and
monitor 2 when an alarm is detected.
1 Press the [MENU] button.
The MENU indicator lights up and the <MAIN MENU> is
displayed.
2 Turn the jog dial to select “2.RECORD
SET” and then turn the shuttle dial
clockwise.
The <RECORD SET> screen is displayed.
3 Turn the jog dial to select “8.ALARM
OPERATION SET” and then turn the
shuttle dial clockwise.
The <ALARM OPERATION SET> screen is displayed.
4 Turn the shuttle dial clockwise.
“OFF” flashes for “ALARM RETRIGGER”.
5 Turn the jog dial to select “ON” and
then turn the shuttle dial clockwise.
The cursor moves to “MAIN MON. DISPLAY”.
Setting alarm operation and display
CH01 T-1 LEVEL : OFF MODE : A
A
MENU
<ALARM OPERATION SET>
ALARM RETRIGGER : OFF
MAIN MON. DISPLAY : FULL
ALARM PRIORITY : LAST
MON.2 DISPLAY : NC
<ALARM OPERATION SET>
ALARM RETRIGGER : OFF
MAIN MON. DISPLAY : FULL
ALARM PRIORITY : LAST
MON.2 DISPLAY : NC
<ALARM OPERATION SET>
ALARM RETRIGGER : ON
MAIN MON. DISPLAY : FULL
ALARM PRIORITY : LAST
MON.2 DISPLAY : NC