Specifications3
226 English
INTRODUCTION SETTINGS NETWORK
CONTROL
NETWORK
OPERATION
NETWORK
SETTINGS
OTHEROPERATION
CTL9 Alarm reset input
[No-volt contacts]
CTL10 Warning output
[DC5V/5.7kΩ, Active Low]
CTL11 Normal recording
area disk full warning output
[DC5V/5.7kΩ, Active Low]
CTL12 Non rec output/
VIDEO LOSS
[DC5V/5.7kΩ, Active Low]
CTL13 Backup remaining
amount/ Timer recording
output
[DC5V/5.7kΩ, Active Low]
CTL14 Alarm output
[Relay DC24V MAX. 1A
AC125V MAX. 0.3A
Normally open]
Input/output terminals Signal level Input/output circuit
0V
Open
ground
input
100ms or more
10k
100k
5V
1k
IC
74HC597
Terminal
0V
5V
Warning conditions established
(HDD error, FAN error detected)
Q
2SC4081
R
10k
R
10k
R
4.7k
R
5V
1k
IC
LC87F2832AU
Terminal
0V
5V
Warning conditions established
(no space in normal recording area)
Q
2SC4081
R
10k
R
10k
R
4.7k
R
5V
1k
IC
LC87F2832AU
Terminal
0V
5V
Stop recording
Q
2SC4081
R
10k
R
10k
R
4.7k
R
5V
1k
IC
LC87F2832AU
Terminal
0V
5V
Warning conditions established
(no space in archive area)
Q
2SC4081
R
10k
R
10k
R
4.7k
R
5V
1k
IC
LC87F2832AU
Terminal
0V
Open
Start alarm
recording
Finish alarm
recording