150 English
ADVANCED MENU SET8
INTRODUCTION SETTINGS NETWORK
CONTROL
NETWORK
OPERATION
NETWORK
SETTINGS
OTHEROPERATION
Settings are required when a remote control camera(s) is
connected with the digital video recorder.
Through making the connections by following the procedure
below, you can control a camera(s) in the full screen mode.
Connections necessary for remote operation:
z Connect coaxial control cameras to the VIDEO terminal.
z Connect the Sanyo RS-485 control camera to the RS-485
(RJ-11) terminal.
z Connect another maker’s RS485/422 control camera to the
2ND RS485/422 terminal.
z If “ADDRESS” in the <RS-485 SET> screen (JP.121) is
set to between “001” and “008”, camera control settings
can be performed. Camera control settings are not
available if “ADDRESS” is set to “000” or between “009”
and “127”.
z
Before configuring trigger actions, be sure to configure
the settings under “ALARM REC MODE SET” and
“PROTOCOL/ADDRESS SET”.
1 Press the [MENU] button.
The MENU indicator lights up and the <MAIN MENU> is
displayed.
2 Turn the jog dial to select
“8.ADVANCED MENU SET” and then
turn the shuttle dial clockwise.
The <ADVANCED MENU SET> screen is displayed.
3 Turn the jog dial to select “3.CAMERA
CONTROL SET” and then turn the
shuttle dial clockwise.
The <CAMERA CONTROL SET> screen is displayed.
4 Turn the jog dial to select
“1.PROTOCOL/ADDRESS SET” and
then turn the shuttle dial clockwise.
The <PROTOCOL/ADDRESS SET> screen is displayed.
5 Turn the jog dial to select the camera
number corresponding to a connected
dome camera and then turn the shuttle
dial clockwise.
“OFF” flashes for “PROTOCOL”.
On the DSR-5709P, cameras No. 01-09 are displayed.
6 Turn the jog dial to select a protocol and
then turn the shuttle dial clockwise.
The cursor moves to the next camera number.
[Settings] ( indicates default setting)
Camera control settings
MENU
<CAMERA CONTROL SET>
1. PROTOCOL/ADDRESS SET ->
2. ALARM REC TRIGGER SET ->
Setting Description
OFF No protocol
SANYO RS485 SANYO RS485
BBV COAX
BBV COAX
(Also supports AUX commands.)
PELCO COAX PELCO COAX
2ND RS-485/422 2ND RS-485/422
COAX (H-SSP) COAX (H-SSP)
<PROTOCOL/ADDRESS SET>
CH PROTOCOL ADD. CH PROTOCOL ADD.
01 OFF --- 09 OFF ---
02 OFF --- 10 OFF ---
03 OFF --- 11 OFF ---
04 OFF --- 12 OFF ---
05 OFF --- 13 OFF ---
06 OFF --- 14 OFF ---
07 OFF --- 15 OFF ---
08 OFF --- 16 OFF ---
2ND RS-485/422 PROTOCOL : OFF 9600bps
<PROTOCOL/ADDRESS SET>
CH PROTOCOL ADD. CH PROTOCOL ADD.
01 OFF --- 09 OFF ---
02 OFF --- 10 OFF ---
03 OFF --- 11 OFF ---
04 OFF --- 12 OFF ---
05 OFF --- 13 OFF ---
06 OFF --- 14 OFF ---
07 OFF --- 15 OFF ---
08 OFF --- 16 OFF ---
2ND RS-485/422 PROTOCOL : OFF 9600bps
<PROTOCOL/ADDRESS SET>
CH PROTOCOL ADD. CH PROTOCOL ADD.
01 SANYO RS-485 001 09 OFF ---
02 OFF --- 10 OFF ---
03 OFF --- 11 OFF ---
04 OFF --- 12 OFF ---
05 OFF --- 13 OFF ---
06 OFF --- 14 OFF ---
07 OFF --- 15 OFF ---
08 OFF --- 16 OFF ---
2ND RS-485/422 PROTOCOL : OFF 9600bps