Sanyo DSR-5709P DVR User Manual


 
RECORD SET3
English 193
Audio can be recorded together with images during alarm
recording. Note, however, that since this audio data is also
stored in the recording area, the recording time for this area
decreases.
6 Set “AUDIO RECORDING”.
[Settings] ( indicates default setting)
z The settings for audio recording are restricted by the
settings for “ALARM INTERLEAVE (Step 7)” as follows:
ONLY/SW/ALL:
Audio recording is enabled when “REC RATE (Step 8)” is
set to 1 FPS or more.
ALL (P-1
4):
Audio recording is enabled when “REC RATE” for any one
of the program-registered cameras is set to 1 FPS or more.
ONLY (P-1
4):
Audio recording is disabled.
z If audio recording is unavailable due to restrictions,
“AUDIORECORDING” will be forcibly switched to “OFF”
when you click the [SAVE] button even if it is set to “ON”.
7 Set “ALARM INTERLEAVE” to the
desired recording pattern.
[Settings] ( indicates default setting)
z In the program mode, there is a time lag of approximately
up to one second between the alarm occurrence and start
of recording, depending on the setting values of the
recording rate.
8 Set “REC RATE” to the desired
recording rate.
[Settings] ( indicates default setting)
z The letter “A” is displayed in front of recording rates that
can be set for audio recording.
z If “ALARM INTERLEAVE (step 7)” is set to program mode,
you cannot select the recording rate.
“***FPS” is automatically displayed when you click the
[SAVE] button.
z When only one camera is connected, recording is
performed at 25 FPS even if 50 FPS is set.
z When two or more cameras are connected and 50 FPS is
set, the actual recording rate is roughly the recording rate
divided by the number of cameras. (Example: When 4
cameras are connected and the recording rate setting is 50
FPS, the actual recording rate is 12.5 FPS)
9 Set “DURATION” to the desired alarm
recording duration.
[Settings] ( indicates default setting)
Setting audio recording
Setting Description
OFF Audio is not recorded.
ON Audio is recorded.
Setting the alarm interleave
Setting Description
ONLY
Video is recorded only from cameras with an
alarm occurring.
SW
Recording is switched between video from a
camera for which an alarm has occurred and
video from all connected cameras.
ALL
For all the connected cameras, video recording
starts at the same time when any one of the
cameras receives an alarm.
ONLY (P-1)
ONLY (P-2)
ONLY (P-3)
ONLY (P-4)
<“ONLY” program mode>
When a connected camera registered in the
program recording setting receives an alarm,
video recording starts at a recording rate
specified in the program.
z Specify the program you want to apply from
“P-1” to “P-4”.
z Audio recording is not available.
ALL (P-1)
ALL (P-2)
ALL (P-3)
ALL (P-4)
<“ALL” program mode>
When any one of the connected cameras
registered in the program recording setting
receives an alarm, video recording starts for all
the connected cameras at a recording rate
which was independently specified for each
connected camera in the program.
z Specify a program you want to apply from “P-
1 to P-4”.
z Audio recording is available only when any
one of the cameras has a recording rate of 1
FPS or more.
Setting Description
A50, A25, A16.67, A12.5,
A8.333, A6.25, A5, A4.167,
A3.571, A3.125, A2.778,
A2.5, A2.273, A1.923,
A1.667, A1.471, A1.316,
A1.19, A1.087, A1
Recording is performed at the
selected recording rate (unit:
FPS). (Audio can be recorded.)
0.5, 0.333, 0.25, 0.2, 0.1,
0.05, 0.033
Recording is performed at the
selected recording rate (unit:
FPS). (Audio cannot be recorded.)
Setting Description
5SEC, 10SEC, 20SEC,
40SEC, 1MIN, 2MIN, 3MIN,
4MIN, 5MIN, 10MIN, 15MIN
Records for the set duration for
each alarm.
CC
Records while an alarm is
activated (Recording continues
for five seconds even if less than
five seconds).