Sanyo DSR-5709P DVR User Manual


 
ADVANCED MENU SET8
English 151
z “COAX” stands for coaxial control and the video signal and
camera control signal. This requires no further wiring for
signal control.
7 Use the same procedure to set the
connection channels of other dome
cameras.
8 When “2ND RS485/422” is selected for
“PROTOCOL”, turn the jog dial to select
“2ND RS485/422 PROTOCOL”, and turn
the shuttle clockwise.
9 Turn the jog dial to select the protocol
to set and then turn the shuttle dial
clockwise.
z From the data speed options (2400/4800/9600bps) for the
protocol you select for “2nd RS485/422 PROTOCOL”,
select one that is compatible with the data speed of the
camera.
z Camera control address
The camera address is a fixed value and is as follows.
If a protocol other than SANYO RS-485 or 2ND RS485/
RS422 is selected, “---” is displayed for the cameral control
address.
On the DSR-5709P, CH1-CH9 are available.
*1 Cannot be operated from a VSP-9000 controller.
10 Once the settings are completed on the
<PROTOCOL/ADDRESS SET> screen,
turn the shuttle dial counter-clockwise.
The display returns to the <CAMERA CONTROL SET>
screen.
<PROTOCOL/ADDRESS SET>
CH PROTOCOL ADD. CH PROTOCOL ADD.
01 SANYO RS-485 001 09 OFF ---
02 BBV COAX --- 10 OFF ---
03 PELCO COAX --- 11 OFF ---
04 2ND RS-485/422 004 12 OFF ---
05 OFF --- 13 OFF ---
06 OFF --- 14 OFF ---
07 OFF --- 15 OFF ---
08 OFF --- 16 OFF ---
2ND RS-485/422 PROTOCOL : OFF 9600bps
<PROTOCOL/ADDRESS SET>
CH PROTOCOL ADD. CH PROTOCOL ADD.
01 SANYO RS-485 001 09 OFF ---
02 BBV COAX --- 10 OFF ---
03 PELCO COAX --- 11 OFF ---
04 2ND RS-485/422 004 12 OFF ---
05 OFF --- 13 OFF ---
06 OFF --- 14 OFF ---
07 OFF --- 15 OFF ---
08 OFF --- 16 OFF ---
2ND RS-485/422 PROTOCOL : OFF 9600bps
DVR/
RS-485
address
Camera control
address
DVR/
RS-485
address
Camera control
address
DVR1:001 CH1 001 DVR2:002 CH1 017
CH2 002 CH2 018
CH3 003 CH3 019
CH4 004 CH4 020
CH5 005 CH5 021
CH6 006 ••
CH7 007 ••
CH8 008 ••
CH9 009 DVR8:008 CH1 113
CH10 010 CH2 114
CH11 011 CH3 115
CH12 012 CH4 116
CH13 013 CH5 117
CH14 014 ••
CH15 015 CH15 127
CH16 016 CH16 000
*1
<CAMERA CONTROL SET>
1. PROTOCOL/ADDRESS SET ->
2. ALARM REC TRIGGER SET ->