13 43(<program>): program change command
The command for PROGRAM CHANGE of D-160. The present program number can be
changed to the figure indicated by <program>.
13 44 (<on/off>): click on/off command
The command for setting the metronome on/off of D-160. When ON is set, the
metronome signal will be fed to the track 16 output (analog output only) of D-160.
13 46 (<on/off>): Bar/Beat Resolution ON/OFF command
The command for ON/OFF of the bar/beat resolution function of this equipments' current
program.
13 47 (<midi sync>): Midi Sync Out command
The setup command for MIDI Sync Out mode of this equipments' current program.
13 48 (<MTC offset mode>): MTC offset mode command
The setup command for MTC offset mode of this equipments' current program.
13 49 (<count=3> <on/off> <vari data>): Vari pitch command
13 49 (<count=1> <on/off>): Vari pitch command
The command for setting this equipments' vari pitch ON/OFF and pitch data.
Control of ON/OFF only is possible at <count=1> and both ON/OFF and pitch data can be
set at <count=3>.
14 01 (<signature map>): Signature set command
The command for setting the meter of this equipment. If a new data is registered at the
bar position where a data exists, the former data will be written over. When this command
is received, this equipment will reply with "34 00 (<edit message>)." Upon completing
the registeration, <edit message> will reply with "01 (completed)," or with "10 (over
value error)" if registeration is attempted at a non-existing point or an erroneous figure
is used.
14 02 (<tempo set map>): Tempo set command
The command for tempo set of this equipment. If a new data is registered in a bar/meter
where data already exists, the former data will be written over. When this command is
received, this equipment will reply with "34 00 (<edit message>)." Upon completing the
registeration, <edit message> will reply with "01 (completed)," or with "10 (over value
error)" if registeration is attempted at a non-existing point or an erroneous figure is
used.
14 03 : Tempo map all erase command
When this command is received, this equipment will erase all meter and tempo data in
the current program and thus return it to the default state (meter=4/4, tempo: =120).
Also, when this command is received, this equipment will reply with "34 00 (<edit
message>)." Upon completing the registeration, <edit message> will reply with "01
(completed)," or with "10 (over value error)" if registeration is attempted at a non-existing
point or an erroneous figure is used.
14 04 (<mmc time>): Preroll time set command
The command for setting the current program preroll time at the figure indicated by
<mmc time>.
14 06 (<frame rate>): Frame rate set command
The command for setting the current program frame rate at the figure indicated by
<frame rate>.