PLC User's Manual - Analog Control Edition
FX3U-4DA (4-channel Analog Output)
5.4.19 BFM #61: Error status data automatic transfer-to data register specification
Setting range: 0 to 7999
Initial value: K200
Numeric data type: Decimal (K)
Use this function to automatically transfer the error status data (BFM #29) to the data register specified in
BFM #61.
When an error is detected, data will be automatically transferred from FX
3U-4DA to the PLC. For this reason,
the PLC does not need a program for reading data, and the scan time of the PLC can be shortened.
For a detailed description of the error status (BFM #29), refer to Subsection 5.4.12.
1. If "BFM #61 = K200 (initial value)"
2. Cautions regarding error status automatic transfer function setting
If a data is already specified for the other automatic transfer functions, do not specify the same data
register.
This function is valid by turning on b0 of the status automatic transfer function setting (BFM #60).
When a value out of the above setting range is set, b9 of the error status BFM #29 is turned on.
The data set in BFM #61 will be retained in the EEPROM.
3. Cautions regarding EEPROM writing
If data is set in BFM #0, #5, #10 to #17, #32 to #35, #50 to #54 or #60 to #63, the data will be written in the
EEPROM of FX
3U-4DA.
Do not turn off the power immediately after writing values in these buffer memories.
The maximum number of EEPROM rewritable times is 10,000. Therefore, when creating a program, do not
frequently write data in the above buffer memories (BFM).
Specified data
register
Description
D200 Value of error status (BFM #29)