Mitsubishi Electronics MELSEC-F Home Theater Server User Manual


 
H-25
4 Programming
4.10 Error Status
FX
3G
/FX
3U
/FX
3UC
PLC User's Manual - Analog Control Edition
FX
3U
-3A-ADP (2-channel analog Input, 1-channel analog output)
A
Common Items
B
FX
3U
-4AD
FX
3UC
-4AD
C
FX
3U
-4AD-ADP
D
FX
3G
-2AD-BD
E
FX
3U
-4DA
F
FX
3U
-4DA-ADP
G
FX
3G
-1DA-BD
H
FX
3U
-3A-ADP
I
FX
3U
-4AD-PT
-ADP
J
FX
3U
-4AD-PTW
-ADP
2. Program Example 1 (FX3G, FX3U, FX3UC Series PLC)
*1. "1st" for the FX3G PLC.
3. Program Example 2 (FX3U, FX3UC Series PLC)
Y000
M0
M8000
M1
M2
M4
M5
M6
M7
Y001
Y002
Y004
Y005
Y006
Y007
Detects over-scale in channel 1 of
the 3rd adapter.
Detects over-scale in channel 2 of
Output data setting error of the 3rd
adapter.
EEPROM error in 3rd adapter
Averaging time setting error in
3rd adapter
Hardware error in 3rd 3A-ADP
Communication data error in 3rd
3A-ADP
MOV
D8288 K4M0
*1
*1
*1
*1
*1
the 3rd adapter.
*1
*1
Y000
D8268.0
Y001
D8268.1
Y002
D8268.2
Y004
D8268.4
Y005
D8268.5
Y006
D8268.6
Y007
D8268.7
Detects over-scale in channel 1 of
the 1st adapter.
Detects over-scale in channel 2 of
the 1st adapter.
Output data setting error of the 1st
adapter.
EEPROM error in 1st adapter
Averaging time setting error in
1st adapter
Hardware error in 1st 3A-ADP
Communication data error in 1st
3A-ADP