B-9
2 Specifications
2.4 Input Mode (Characteristics) BFM #0
A
Common Items
B
FX
3U
-4AD
FX
3UC
-4AD
C
FX
3U
-4AD-ADP
D
FX
3G
-2AD-BD
E
FX
3U
-4DA
F
FX
3U
-4DA-ADP
G
FX
3G
-1DA-BD
H
FX
3U
-3A-ADP
I
FX
3U
-4AD-PT
-ADP
J
FX
3U
-4AD-PTW
-ADP
FX
3G
/FX
3U
/FX
3UC
PLC User's Manual - Analog Control Edition
FX3U-4AD/FX3UC-4AD (4-channel Analog Input)
3. Current input characteristics [-20 to +20mA] (Input mode: 6 to 8)
Set input mode: 6
Input type: Current input
Analog input range: -20 to +20mA
Digital output range: -16000 to +16000
Offset/gain adjustment: Possible
Set input mode: 7
Input type: Current input
Analog input range: -20 to +20mA
Digital output range: -4000 to +4000
Offset/gain adjustment: Possible
Set input mode: 8
Input type: Current input
(analog value direct indication)
Analog input range: -20 to +20mA
Digital output range: -20000 to +20000
Offset/gain adjustment: Impossible
Digital value
+16000
-16000
-20mA
+20mA
0
+16320
+20.4mA
-16320
-20.4mA
Current
Input
+4000
-4000
-20mA
+20mA
0
Digital value
+4080
+20.4mA
-4080
-20.4mA
Current
Input
+20000
-20000
-20mA
+20mA
0
Digital value
+20400
+20.4mA
-20400
-20.4mA
Current
Input